Simulation of Nonazeotropic Refrigerant Mixtures for Use in a Dual-Circuit Refrigerator/Freezer with Countercurrent Heat Exchanges. |
Author |
Bare, J. C. ;
Gage, C. L. ;
Radermacher, R. ;
Jung, D. S. ;
|
CORP Author |
Maryland Univ., College Park. Dept. of Mechanical Engineering.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
1992 |
Year Published |
1992 |
Report Number |
R-817111; EPA/600/A-92/274; |
Stock Number |
PB93-131688 |
Additional Subjects |
Refrigerants ;
Air pollution abatement ;
Environmental chemical substitutes ;
Refrigerators ;
Computerized simulation ;
Pollution sources ;
Heat exchangers ;
Freezers ;
Energy consumption ;
Performance evaluation ;
Freons ;
Fluorohydrocarbons ;
Dual cycle cooling systems ;
Chlorohydrocarbons ;
Nonazeotropic refrigerant mixtures ;
Montreal Protocol
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB93-131688 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
25p |
Abstract |
The paper discusses the simulation of Non-azeotropic Refrigerant Mixtures (NARMs) for use in a dual-circuit refrigerator/freezer (RF) with countercurrent heat exchangers. The simulated RF has two complete and independent refrigeration cycles for its two compartments. It uses a NARM in each cycle and countercurrent heat exchangers throughout. In a standard cabinet, the RF is simulated to provide energy savings of 24 percent compared to current U.S. RF designs. The NARMs modeled with the best performance are R-32/-152a, R-32/-142b, and R-22/-142b. An 18 percent improvement can be expected from the dual-circuit system using R-12 alone, and an additional 6 percent improvement can be gained by replacing R-12 with the selected NARMs in countercurrent heat exchangers. Advantages of the system include greatly reduced energy consumption, easy temperature and humidity control for each compartment, no humidity or odors transferred between compartments, and increased time between defrost cycles. Disadvantages include additional hardware requirements, compressor size, and the difficulties of using a NARM. |
Supplementary Notes |
Presented at ASHRAE Meeting, Indianapolis, IN., June 23-25, 1991. See also PB90-262833. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |