Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 6 OF 13

Main Title Particulate Measurement - Dilution Tunnel Stabilization.
Author Danielson, Eugene ;
CORP Author Environmental Protection Agency, Ann Arbor, MI. Standards Development and Support Branch.
Year Published 1978
Report Number LTDP-78-14;
Stock Number PB-289 879
Additional Subjects Particles ; Air pollution ; Stability ; Concentration(Composition) ; Exhaust emissions ; Dilution tunnels
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-289 879 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 6p
Abstract Particulate testing was conducted to determine the number of hot-start UDDS (LA-4) cycles that must be driven to stabilize a clean 18-inch diameter dilution tunnel. The results of this investigation indicate that valid particulate measurements can be obtained with a clean dilution tunnel; i.e., essentially no LA-4 cycles are required to stabilize the dilution tunnel with respect to particulate material. This conclusion is based on the observation that slightly higher than average particulate levels (taken with stabilized tunnel) were measured during the first (actually first two) LA-4 test after tunnel cleaning. If particulate material is being lost to the dilution tunnel walls it is minimal and not significant compared to normal test variability.
NTIS Title Notes Technical rept..
PUB Date Free Form Nov 78
Category Codes 13B; 68A
NTIS Prices PC A02/MF A01
Primary Description 200/05
Document Type NT
Cataloging Source NTIS/MT
Control Number 323754228
Origin NTIS
Type CAT