Main Title |
Arsenic removal from drinking water by coagulation/filtration U.S. EPA demonstration project at Village of Pentwater, MI / {electronic resource} : |
Author |
J. M. VALIGORE ;
A. S. C. Chen ;
W. E. CONDIT ;
L. Wang ;
Valigore, Julia M.
|
Other Authors |
|
CORP Author |
Battelle, Columbus, OH.; National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div. |
Publisher |
National Risk Management Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, |
Year Published |
2008 |
Report Number |
EPA-68-C-00-185; EPA/600/R-08/011 |
Stock Number |
PB2008-108870 |
OCLC Number |
216880754 |
Subjects |
Water--Purification--Arsenic removal ;
Water--Purification--Coagulation ;
Water--Purification--Membrane filtration ;
Water--Purification--Michigan--Pentwater (Village)
|
Additional Subjects |
Drinking water ;
Arsenic removal ;
Demonstration project ;
Village of Pentwater MI ;
Treatment system ;
Macrolite media ;
Evaluation
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600/R-08/011 |
|
Headquarters Library/Washington,DC |
04/04/2008 |
NTIS |
PB2008-108870 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Edition |
Final performance evaluation report |
Collation |
{76} p. : ill. : digital, PDF file |
Abstract |
This report documents the activities performed during and the results obtained from the arsenic removal treatment technology demonstration project at the Village of Pentwater, MI facility. The objectives of the project were to evaluate: (1) the effectiveness of Kineticofs FM-260-AS treatment system using MacroliteR media in removing arsenic to meet the maximum contaminant level (MCL) of 10 Eg/L, (2) the reliability of the treatment system for use at small water facilities, (3) the required system operation and maintenance (O and M) and operator skill levels, and (4) the capital and O and M cost of the technology. The project also characterized water in the distribution system and residuals generated by the treatment process. The types of data collected included system operation, water quality, process residuals, and capital and O and M cost. After review and approval of the engineering plan by the State, the FM-260-AS treatment system was installed and became operational on November 22, 2005. The system consisted of one 96-in x 96-in steel contact tank and two 60-in x 96-in steel pressure tanks configured in parallel. Each pressure tank was loaded with 40 ft(sup 3) of Macrolite (Trade Name) media to which filtration rates up to 9.3 gpm/ft(sup 2) were applied The system used an existing chlorination system to oxidize As(III) and Fe(II) and the contact tank to improve the formation of As(V)-laden iron particles prior to filtration. An iron addition system was installed midway through the study to improve arsenic removal. On average, the system operated at approximately 350 gal/min (gpm) for 5.1 hr/day, producing 39,185,000 gal of water through December 8, 2006. This average flowrate corresponded to a contact time of 6.8 min and a filtration rate of 8.9 gpm/ft(sup 2). Several problems were encountered during the demonstration study, including programmable logic controller (PLC) settings, backwash and service flowrates, media loss, influent pressure spikes, and chlorine addition. The actions taken to address these problems are detailed in the report. |
Notes |
"June 2008." "EPA/600/R-08/011." Title from title screen (viewed on March 31, 2008). Includes bibliographical references (p. 45-46). |
Place Published |
Cincinnati, OH : |
Supplementary Notes |
See also Six Month Evaluation, PB2008-101563. Sponsored by National Risk Management Research Lab., Cincinnati, OH. Water Supply and Water Resources Div. |
Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Access Notes |
Mode of access: Internet. System requirements: Adobe Acrobat Reader. |
Corporate Au Added Ent |
National Risk Management Research Laboratory (U.S.). Water Supply and Water Resources Division. |
PUB Date Free Form |
Jan 2008 |
Category Codes |
68D; 57U; 99A; 43F; 91A |
NTIS Prices |
PC A06 |
BIB Level |
m |
Medium |
electronic resource |
Cataloging Source |
OCLC/T |
Control Number |
019000490 |
OCLC Time Stamp |
20080331144746 |
Language |
eng |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01973nam 2200445Ia 45020 |