Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 32 OF 44

Main Title National Dust Collector Model 850 : variable rod module venturi scrubber evaluation /
Author Calvert, Seymour,
Other Authors
Author Title of a Work
Barbarika, Harry,
Lake, Charles F.,
Barbarika, Harry F.,
CORP Author Air Pollution Technology, Inc., San Diego, Calif.;Industrial Environmental Research Lab., Research Triangle Park, N.C.
Publisher Environmental Protection Agency, Office of Research and Development ; For sale by the National Technical Information Service,
Year Published 1976
Report Number EPA-600/2-76-282; EPA-68-02-1869; EPA-ROAP-21ADM-029
Stock Number 22161
OCLC Number 04062429
ISBN pbk.
Subjects Dust control ; Scrubber (Chemical technology)
Additional Subjects Air pollution control equipment ; Dust collectors ; Scrubbers ; Particle size ; Performance evaluation ; Economics ; Cost estimates ; Mathematical models ; Numerical analysis ; Impactors ; Iron and steel industry ; Efficiency ; Operating costs ; Venturi scrubbers ; Cascade impactors
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=910168EW.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA-600/2-76-282 Research Triangle Park Library/RTP, NC 06/20/2003
ELBD ARCHIVE EPA 600-2-76-282 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-2-76-282 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-263 617 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation ix, 53 pages : illustrations ; 28 cm.
Abstract The report gives results of a measurement of the performance of a National Dust Collector Model 850 variable rod module venturi scrubber at an industrial installation. Fine particle collection efficiency as a function of particle size was computed from the data collected. The scrubber tower was operated at 1010 std cu meters/min at 35 C with a total pressure drop of 224 cm (88 in.) W.C. with a pressure drop across the venturi module of 178 cm (70 in.) W.C. The emission source was an iron cupola which processes both ductile and gray iron, with the latter producing a higher grain loading. The ductile iron source particulates had a mass mean diameter range of 0.25-0.84 micrometers A (aerodynamic particle diameter) with a standard deviation range of 1.5-2.0. The gray iron source particulates had a mass mean diameter range of 0.54-1.9 micrometers A with a standard deviation range of 1.5-1.8. The overall average collection efficiency for ductile iron melting was 98.7%. For gray iron melting, the average collection efficiency was also 98.7% even though the cupola emission was lower for ductile iron.
Notes Contract no. 68-02-1869, ROAP no. 21ADM-029, program element no. 1AB012. Issued Dec. 1976. Includes bibliographical references (page 32).
Place Published Washington Springfield, Va.
Access Notes Also available via World Wide Web.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Development.
Corp Au Ser Add Ent United States. Environmental Protection Agency. Environmental protection technology series ; EPA-600/2-76-282.
PUB Date Free Form 1976
Series Title Untraced Environmental protection technology series ; EPA-600/2-76-282
NTIS Prices PC A04/MF A01
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20140331095420
Language eng
SUDOCS Number EP 1.23/2:600/2-76-282
Origin OCLC
Type MERGE
OCLC Rec Leader 01809cam 2200397Ii 45020