Main Title |
Acid rain mitigation study. Volumes I and II / |
Author |
Ball, J. G.
|
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory, |
Year Published |
1982 |
Report Number |
EPA/600-S2-82-070 |
OCLC Number |
457242016 |
Subjects |
Acid rain--United States
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-S2-82-070 |
In Binder |
Headquarters Library/Washington,DC |
08/08/2018 |
ELBD ARCHIVE |
EPA 600-S2-82-070 |
In Binder Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
|
Collation |
6 pages : illustrations ; 28 cm |
Notes |
Caption title. At head of title: Project summary. "Dec. 1982." "EPA/600-S2-82-070." |
Contents Notes |
The U.S. EPA has initiated a multi-phased study of the acid rain problem. As part of Phase I, Radian Corporation investigated SO2 emissions and controls in the industrial sector. The primary objective of this work was to provide a consistent set of capital investment and operating costs for flue gas desulfurization (FGD) systems applied to both industrial and electric utility boilers. Retrofit factors and the cost of FGD systems applied to new boilers were addressed. Wet limestone scrubbing and lime spray drying FGD systems were evaluated. In conducting the work to provide a consistent set of capital investment and operating costs for FGD systems retrofitted to existing boilers, the following issues were investigated: 1) Apparent discontinuities in both FGD system capital investment and operating costs as a function of boiler capacity in the region between industrial boilers and small utility boilers. 2) FGD retrofit factors applied to existing boilers based on published reports. 3) Differences between PEDCo Environmental, Inc. and TVA cost estimates for utility boiler FGD systems. These costing issues were examined on the bases of design scope, costing factors (for equipment installation, indirect investment, etc.), year of costs, inherent strengths and weaknesses, and published data of actual system costs. Recommendations are made for the cost bases to use in further acid rain studies. |
Place Published |
Research Triangle Park, N.C. |
Corporate Au Added Ent |
Industrial Environmental Research Laboratory (Research Triangle Park, N.C.) |
PUB Date Free Form |
1982 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20091020142716 |
Language |
eng |
Origin |
OCLC |
Type |
CAT |
OCLC Rec Leader |
02442nam 2200301Ia 45020 |