Main Title |
Magnetic Drum Separator Performance Scalping Trommel Underflow at Nominal Design Conditions. Test No. 4.01, Recovery 1, New Orleans. |
CORP Author |
National Center for Resource Recovery, Inc., Washington, DC.;Municipal Environmental Research Lab., Cincinnati, OH. |
Year Published |
1981 |
Report Number |
EPA-68-01-4423; EPA-600/2-81-100; |
Stock Number |
PB81-213308 |
Additional Subjects |
Materials recovery ;
Reclamation ;
Solid waste disposal ;
Magnetic separators ;
Iron alloys ;
Design ;
Performance tests ;
Performance evaluation ;
Statistical data ;
Municipal wastes ;
Solid wastes ;
NTISEPAORD
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB81-213308 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
71p |
Abstract |
This report describes the first test of the magnetic drum separator that was designed to scalp the underflow of the trommel, or rotary screen, at the New Orleans, Louisiana, resource recovery facility. The objective of the test was to document the performance of the trommel-unders magnetic drum separator with the trommel processing raw municipal solid waste at the nominal design feed rate of 62.5 tph. |