Main Title |
Automatic organic monitoring system for storm and combined sewers / |
Author |
Tulumello, Angelo.
|
CORP Author |
Raytheon Co., Portsmouth, R.I.;National Environmental Research Center, Cincinnati, Ohio. |
Publisher |
National Environmental Research Center, Office of Research and Development, U.S. Environmental Protection Agency, |
Year Published |
1975 |
Report Number |
EPA-670/2-75-067; EPA-68-03-0262; EPA-ROAP-21ASY; 038 |
Stock Number |
PB-244 142 |
OCLC Number |
01728527 |
Subjects |
Storm sewers--Environmental aspects--Analysis. ;
Runoff--Environmental aspects--Analysis. ;
Water--Pollution--Analysis. ;
Water quality management--Analysis.
|
Additional Subjects |
Organic compounds ;
Water analysis ;
Monitors ;
Combined sewers ;
Surface water runoff ;
Water pollution ;
Sampling ;
Instrumentation ;
Recording instruments ;
Carbon ;
Combustion ;
Circuits ;
Process charting ;
Design ;
Total organic carbon ;
Water pollution detection ;
Storm water runoff
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD ARCHIVE |
EPA 670-2-75-067 |
|
Headquarters Library/Washington,DC |
05/28/2013 |
EJBD |
EPA 670-2-75-067 |
|
Headquarters Library/Washington,DC |
05/03/2016 |
EKAM |
EPA 670/2-75-067 |
|
Region 4 Library/Atlanta,GA |
10/23/1998 |
ELBD |
EPA 670-2-75-067 |
|
AWBERC Library/Cincinnati,OH |
12/19/1997 |
NTIS |
PB-244 142 |
Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. |
|
01/01/1988 |
|
Collation |
ix, 70 p. : ill. ; 27 cm. |
Abstract |
Early in the program to develop a stormwater TOC (total organic carbon) system, it was established in report EPA-670/2-74-087 that continuous on-line TOC was the best method for the measurement of stormwater pollution loading. Hardware was assembled that would process stormwater samples containing high suspended solids and that would obtain a continuous signal proportional to the concentration of TOC in the sample. Synthetic samples of municipal raw influent charged with primary sludge were analyzed using the TOC analyzer. Data were also obtained on actual stormwater samples collected during storm events at Boston. Further modifications were made after these observations. Automatic circuitry designed to provide turn on, auto-zero, auto-span and sample line flushing was added to the hardware, and the system was installed at Boston Cottage Farm Storage Facility. Automatic continuous analyses were obtained during storms on site at the Cottage Farm Storage Facility. |
Notes |
Contract no. 68-03-0262; program element no. 1BB034. |