Main Title |
Ventilation research: a review of recent indoor air quality literature : project summary / |
Author |
VanOsdell, Douglas W. ;
Van Osdell, D. W.
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC. Center for Aerosol Technology.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory, |
Year Published |
1994 |
Report Number |
EPA/600-SR-94-180; EPA-R-817083-01-0 |
Stock Number |
PB95-129086 |
OCLC Number |
31960469 |
Subjects |
Ventilation--Research--Bibliography ;
Indoor air pollution--Bibliography
|
Additional Subjects |
Indoor air pollution ;
Space HVAC Systems ;
Air quality ;
Literature surveys ;
Ventilation systems ;
Air conditioners ;
Heating Systems ;
Air flow ;
Air infiltration ;
Environmental transport ;
Microorganisms ;
Permeability ;
Air cleaning systems ;
Buildings ;
Design criteria ;
Air pollution dispersion ;
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-SR-94-180 |
In Binder |
Headquarters Library/Washington,DC |
10/26/2018 |
EKBD |
EPA-600/SR-94-180 |
|
Research Triangle Park Library/RTP, NC |
10/03/2008 |
ELBD ARCHIVE |
EPA 600-SR-94-180 |
In Binder Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 600-SR-94-180 |
|
AWBERC Library/Cincinnati,OH |
05/08/1998 |
EMBD |
EPA/600/SR-94/180 |
|
NRMRL/GWERD Library/Ada,OK |
12/28/2001 |
NTIS |
PB95-129086 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
3 unnumbered pages ; 28 cm. |
Abstract |
Building ventilation and air conditioning systems have traditionally been designed and controlled to maintain occupant thermal comfort at acceptable capital and operating costs, an indoor air quality (IAQ) has not been a primary concern. A literature review was conducted to survey and summarize recent and on-going engineering research into building ventilation, air exchange rate, pollutant distribution and dispersion, and other effects of heating, ventilation, and air conditioning (HVAC) systems on IAQ. The ventilation-related engineering literature was divided into seven major categories: (1) pollutant transport to and into the building envelope; (2) air cleaning systems; (3) flow and pollutant dispersion, (4) room and building flow/dispersion research; (5) HVAC/building design, operation, and control strategies; (6) applied microbial research; and (7) building performance. The significance and status of ventilation-related IAQ research was summarized by research category, and research opportunities were identified within each category. |
Notes |
Caption title. "November 1994." "EPA/600-SR-94-180." "Project summary." |