Record Display for the EPA National Library Catalog

RECORD NUMBER: 273 OF 617

Main Title Indoor Air Pollution in the Residential Environment. Volume I. Data Collection, Analysis and Interpretation.
Author Moschandreas, Demetrios J. ; Stark, John W. C. ; McFadden, James E. ; Morse, Sallie S. ;
CORP Author Geomet, Inc., Gaithersburg, MD.;Department of Housing and Urban Development, Washington, DC. Office of Community Planning and Development.;Environmental Monitoring and Support Lab., Research Triangle Park, NC. Quality Assurance Branch.
Year Published 1978
Report Number GEOMET-EF-688-VOL-1; EPA-68-02-2294; EPA/600/7-78/229A;
Stock Number PB-290 999
Additional Subjects Air pollution ; Energy conservation ; Residential buildings ; Data analysis ; Concentration(Composition) ; Monitoring ; Mathematical models ; Sites ; Carbon monoxide ; Sulfur dioxide ; Nitrogen oxide(NO) ; Nitrogen dioxide ; Carbon dioxide ; Aldehydes ; Ammonia ; Lead(Metal) ; Ozone ; Methane ; Particle ; Sulfates ; Inorganic nitrates ; Indoor air pollution ; Air quality ; Air pollution sampling ; Numerical solution
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-290 999 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 204p
Abstract
A 24-month study was undertaken to characterize the indoor residential air quality. Seventeen residential dwellings were monitored, each for a 14-day period. Air samples were collected from four locations: one outdoor site adjacent to the building; and three indoor sites, the kitchen, bedroom, and living room. 'Continuous' sampling was carried out for CO, SO2, NO, NO2, CO2, O3, CH4, and THC. TSP, RSP, SO=4, NO-3, Pb, ammonia, and aldehydes were monitored intermittently. Aerosol samples were collected for elemental analysis by the Proton Induced X-ray Emission (PIXE) technique. In addition, data on energy parameters, infiltration rates, and family activities were obtained by observations, field experiments, and daily questionnaires, respectively. Each residence was monitored with minimal interference in the daily activities of the occupants; thus, the residential pollutant concentrations were determined under real-life conditions. Finally, the relationship between energy conservation measures and air quality in the indoor environment is examined. The observed indoor air pollutant concentrations were, on the average, not very high; however, persistent moderate and, at times, elevated pollutant levels were observed. The lack of studies concerning the health implications of such levels is briefly discussed.