Record Display for the EPA National Library Catalog
RECORD NUMBER: 1271 OF 2453Main Title | Monitoring Airborne Particulate Mass by Beta Absorption. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Krost, K. J. ; Sawicki, C. R. ; Bell., J. P. ; | |||||||||||
CORP Author | Environmental Sciences Research Lab., Research Triangle Park, N.C. | |||||||||||
Year Published | 1977 | |||||||||||
Report Number | EPA/600/J-77/079; | |||||||||||
Stock Number | PB-278 338 | |||||||||||
Additional Subjects | Particles ; Detectors ; Radiation measuring instruments ; Air pollution ; Design criteria ; Performance evaluation ; Absorption spectra ; Feasibility ; Samples ; Beta particles ; Carbon 14 ; Reprints ; Air pollution detection ; Beta detection | |||||||||||
Holdings |
|
|||||||||||
Collation | 24p | |||||||||||
Abstract | A prototype airborne particulate mass monitor, using the principle of beta radiation absorption, has been fabricated and evaluated on airborne particulate matter. A detection sensitivity of 80 microgram/sq cm was attained. A series of samples were collected, and a comparison was made between the gravimetric and beta absorption results obtained on each sample. This study demonstrated the feasibility of fabricating a fully automated system for the collection and analysis of airborne particulate mass, using the principle of beta absorption attenuation. (Copyright (c) 1977 by Marcel Dekker, Inc.) |