Main Title |
Measurement of strontium-89 and strontium-90 in environmental waters : a tentative reference method / |
CORP Author |
Environmental Monitoring and Support Laboratory (Las Vegas, Nev.). Monitoring Systems Research and Development Division. Quality Assurance Branch, |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Environmental Monitoring and Support Laboratory, Available from National Technical Information Service. |
Year Published |
1976 |
Report Number |
EPA-600/4-76-011; ROAP 22ACW; 1HA327; IHA327 |
Stock Number |
PB-251 312 |
OCLC Number |
02336575 |
Subjects |
Water--Pollution ;
Strontium
|
Additional Subjects |
Strontium isotopes ;
Water pollution ;
Strontium 90 ;
Yttrium isotopes ;
Sampling ;
Measurement ;
Strontium 89
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJED |
EPA 600/4-76/011 |
|
OCSPP Chemical Library/Washington,DC |
02/11/2005 |
ELBD ARCHIVE |
EPA-600-4-76-011 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 600-4-76-011 |
|
AWBERC Library/Cincinnati,OH |
04/16/2018 |
ESAD |
EPA 600-4-76-011 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-251 312 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
iii, 20 pages ; 28 cm. |
Abstract |
A tentative reference method for the measurement of strontium-89 and -90 in environmental waters is described. Samples of environmental water sources are collected, preserved with acid-strontium carrier, and analyzed for strontium-89 and/or strontium-90. Strontium-89 and -90 are separated from the sample water by precipitating with stable strontium carrier as carbonate. The strontium carbonate is dissolved, yttrium-90 separated, the strontium reprecipitated as carbonate, filtered, and counted for the combined strontium-89 and -90 activity. The yttrium-90 is allowed to grow in from the strontium-90 activity; the strontium carbonate is redissolved; the yttrium-90 is separated, precipitated, and counted for the strontium-90 determination. The strontium-89 activity is then determined by difference of the total strontium-89 and -90 and the separate strontium-90 activities. Recoveries are determined from the added and found (recovered) strontium carrier. Counting efficiencies are determined with prepared standard reference samples. Results are reported in pCi/liter. |
Notes |
"ROAP Number 22ACW." "March 1976." |