Record Display for the EPA National Library Catalog

RECORD NUMBER: 17 OF 25

OLS Field Name OLS Field Data
Main Title Impregnation of concrete pipe for corrosion resistance and strength improvement /
Author Ludwig, Allen C.
CORP Author Southwest Research Inst., San Antonio, TX.;Municipal Environmental Research Lab., Cincinnati, OH.
Publisher Municipal Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency ; Available through the National Technical Information Service,
Year Published 1980
Report Number EPA-600/2-80-009; EPA-S-802651; SwRI-11-5016
Stock Number PB80-190234
OCLC Number 06541389
Subjects Sewer-pipe. ; Pipe, Concrete--Corrosion. ; Sulfur in building. ; Sulphur in building
Additional Subjects Sewer pipes ; Concrete pipes ; Field tests ; Corrosion resistance ; Strength ; Impregnating ; Sulfur ; Hydrofluoric acid
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30000A92.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  TD172.E46 600 1980, no.009 Region 1 Library/Boston,MA 04/29/2016
EJAD  EPA 600/2-80-009 Region 3 Library/Philadelphia, PA 03/14/1997
EJBD ARCHIVE EPA 600-2-80-009 Headquarters Library/Washington,DC 01/22/2014
EJBD  EPA 600-2-80-009 Headquarters Library/Washington,DC 03/29/2016
EKAM  TD172.E46 600 1980, no.009 Region 4 Library/Atlanta,GA 11/20/1998
ELBD  EPA 600-2-80-009 AWBERC Library/Cincinnati,OH 01/02/1998
ESAD  EPA 600-2-80-009 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB80-190234 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation x, 50 pages : illustrations ; 28 cm.
Abstract
The program was undertaken to field test concrete sewer pipe that had been impregnated with sulfur or hydrofluoric acid. This program was a follow-on to a previous laboratory study sponsored by EPA entitled, Impregnation of Concrete Pipe, 11024EQE 06/71. In a subsequent grant extension to the program, strength improvements using the sulfur formulations were investigated with a view to reducing costs by elimination of the steel reinforcing in certain sizes of concrete pipe. In 1975, nearly 1400 feet (427 m) of impregnated sewer lines were installed in four Texas cities, including Dallas, Beaumont, Pecos, and Harlingen. These lines have been monitored since that time and the results of this monitoring, as well as a discussion of the strength improvement due to sulfur impregnation, are reported.
Notes
Grant no. S802651.