Main Title |
Survey of users of the EPA - reference method for measurement of non-methane hydrocarbons in ambient air / |
Author |
Reckner, Louis R.
|
CORP Author |
Scott Environmental Technology, Inc., Plumsteadville, Pa.;Environmental Protection Agency, Washington, D.C. Office of Research and Development. |
Publisher |
Quality Assurance and Environmental Monitoring Laboratory, National Environmental Research Center, |
Year Published |
1974 |
Report Number |
EPA/650-4-75-008; EPA-68-02-1206; EPA-ROAP-26AAF |
Stock Number |
PB-247 515 |
OCLC Number |
15129101 |
Subjects |
Air--Pollution--Measurement ;
Hydrocarbons ;
Environmental monitoring
|
Additional Subjects |
Air pollution ;
Hydrocarbons ;
Gas analysis ;
Industrial plants ;
Instruments ;
Field tests ;
Accuracy ;
Gas chromatography ;
Performance evaluation ;
Precision ;
Monitors ;
Plant location ;
Surveys ;
Performance standards ;
Standards ;
Air pollution sampling
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 650-4-75-008 |
|
Headquarters Library/Washington,DC |
06/08/2015 |
EKBD |
EPA-650/4-75-008 |
|
Research Triangle Park Library/RTP, NC |
08/29/2017 |
ELBD ARCHIVE |
EPA 650-4-75-008 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
NTIS |
PB-247 515 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
42 pages : illustrations, tables ; 28 cm. |
Abstract |
Scott performed a survey of users of the EPA Reference Method for measurement of non-methane hydrocarbons in ambient air which resulted in the compilation of a list of 188 NMHC analyzers operated by 70 organizations. Field evaluations were performed on instruments operated by 16 of the users. The accuracy of the NMHC data being obtained by the 16 users of the reference method was determined by presenting a series of 5 gas mixtures in high-pressure cylinders for analysis by each operator. The results for the mixture containing NMHC at a concentration close to the 0.24 ppm-C ambient air standard showed that substantial errors existed in current NMHC data. An analysis of the data showed that the inaccuracies in current data make it impossible to determine whether ambient air quality is in compliance with the standard. The major factors contributing to data errors are discussed, and recommendations for improving data quality are presented. |
Notes |
"December 1974." "EPA/650-4-75-008." Prepared for the U.S. Environmental Protection Agency. Contract Number: 68-02-1206 |