Record Display for the EPA National Library Catalog

RECORD NUMBER: 20 OF 66

OLS Field Name OLS Field Data
Main Title Environmental monitoring near industrial sites polychloronaphthalenes /
Author Erickson, M. D. ; Zweidinger, R. A. ; Michael, L. C. ; Pellizzari., E. D.
Other Authors
Author Title of a Work
Erickson, Mitchell D.
DeCarlo, Vincent.
CORP Author Research Triangle Inst., Research Triangle Park, N.C.;Environmental Protection Agency, Washington, D.C. Office of Toxic Substances.
Publisher U.S. Environmental Protection Agency, Office of Toxic Substances,
Year Published 1977
Report Number EPA-560/6-77-019;68-01-1978; EPA-68-01-1978
Stock Number PB-281 687
OCLC Number 28463562
Subjects Environmental monitoring--United States ; Naphthalene--Measurement--United States ; Polycyclic aromatic hydrocarbons--Toxicity ; Factory and trade waste--Measurement--United States
Additional Subjects Environmental surveys ; Chemical analysis ; Industrial wastes ; Chlorine organic compounds ; Monitoring ; Soil analysis ; Sediments ; Field tests ; Gas analysis ; Water analysis ; Samplers ; Laboratory equipment ; Quality control ; Polychlorinated naphthalenes ; Air pollution detection ; Water pollution detection
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100ANFZ.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJED  EPA-560/6-77-019 OCSPP Chemical Library/Washington,DC 07/23/1993
NTIS  PB-281 687 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation 241 p. : ill., maps ; 28 cm.
Abstract
This research program was initiated to evaluate possible environmental contamination by polychlorinated naphthalenes (PCNs). The program included sampling and analytical method development and the collection and analysis of field samples. A glass fiber filter and two precleaned polyurethane foam plugs in tandem were used for PCN collection. Recovery of the PCNs from the foam and filter was accomplished by triple extraction with toluene. The concentrated extract was chromatographed on a silica gel column and the final volume reduced to 2 ml in a Kuderna-Danish apparatus. Samples were analyzed by gas chromatograph/quadrupole mass spectrometer/computer. The instrument was operated in the multiple ion detection mode which permitted the detection of < 50 pg of a PCN isomer (approximately 0.3 ng/cu m in air). The presence of PCNs was confirmed from full scan mass spectra or by monitoring the chlorine isotope ratio. Air, water, soil, sediment and biota were collected from sites near a PCN manufacturer, and six potential users. PCNs were found at all sites sampled although appreciable quantities were found at only three sites, near the manufacturer and two possible users.
Notes
"Research Triangle Institute; contract no. 68-01-1978; project officer: Dr. Vincent J. DeCarlo." "560/6-77-019." "July 1977." Includes bibliography (p. 164-167)