Record Display for the EPA National Library Catalog
RECORD NUMBER: 68 OF 86Main Title | Sulfur Dioxide Conversion under Corona Discharge Catalysis. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Brown, W. R. ; Ston, E. E. ; | |||||||||||
CORP Author | General Electric Co., Schenectady, N.Y. Advanced Technology Labs. | |||||||||||
Year Published | 1965 | |||||||||||
Report Number | PH-86-65-2; | |||||||||||
Stock Number | PB-185 465 | |||||||||||
Additional Subjects | ( Air pollution ; Sulfur compounds) ; ( Waste gases ; Electric discharges) ; ( Sulfur compounds ; Oxidation) ; Ultraviolet radiation ; Dioxides ; Chemical reactions ; Sulfur dioxide ; Flue gases ; Electric corona | |||||||||||
Holdings |
|
|||||||||||
Collation | 26p | |||||||||||
Abstract | Synthetic flue gas was exposed to ultraviolet radiation and to a corona discharge in laboratory type reactors and the efficiency of SO2 oxidation to SO3 for each of these methods was compared. For the conditions studied, corona treatment appeared to be superior to ultraviolet, showing efficiencies of 300 and 1470 cu. cm of the flue gas per watt hour for SO2 conversions of 99.5 and 75%, respectively. (Author) |