Record Display for the EPA National Library Catalog
RECORD NUMBER: 13 OF 85Main Title | Assessment of the Adequacy of the Appendix F Quality Assurance Procedures for Maintaining CEMS (Continuous Emission Monitoring Systems) Data Accuracy (Status Report No. 1). | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CORP Author | Entropy Environmentalists, Inc., Research Triangle Park, NC.;Environmental Monitoring Systems Lab., Research Triangle Park, NC. | |||||||||||
Year Published | 1983 | |||||||||||
Report Number | EPA-68-02-3431; EPA-600/4-83-047; | |||||||||||
Stock Number | PB83-264440 | |||||||||||
Additional Subjects | Electric power plants ; Air pollution control equipment ; Scrubbers ; Quality assurance ; Auditing ; Performance evaluation ; Sulfur dioxide ; Nitrogen oxides ; Oxygen ; Carbon dioxide ; Continuous emission monitoring systems | |||||||||||
Holdings |
|
|||||||||||
Collation | 80p | |||||||||||
Abstract | This report summarizes the first year's audit results of Continuous Emission Monitoring Systems (CEMS) installed at scrubber-equipped power plants. The audits were conducted to support a draft quality assurance appendix for 40 CFR 60 entitled 'Quality Assurance Procedures for Gas CEMS Used for Compliance'. The procedures call for a quality performance audit of the CEMS using certified cylinder gas or reference method tests. Audit data have been collected for sulfur dioxide, nitrogen oxides, oxygen and carbon dioxide. EDC, Contraves, Lear Seigler and DuPont CEMS have been audited, with the results indicating the need for frequent audits with effective corrective action to be taken when excessive inaccuracies are measured. |