Record Display for the EPA National Library Catalog
RECORD NUMBER: 100 OF 114Main Title | Sampling and analysis for polychlorinated dibenzo-P-dioxins and dibenzofurans in ambient air. {microfiche} | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Harless, R.L. ; Lewis, R. G. ; McDaniel, D. D. ; Dupuy., A. E. | |||||||||||
CORP Author | Environmental Protection Agency, Research Triangle Park, NC. Atmospheric Research and Exposure Assessment Lab. | |||||||||||
Publisher | U.S. Environmental Protection Agency, Atmospheric Research and Environmental Assessment Laborary. | |||||||||||
Year Published | 1990 | |||||||||||
Report Number | EPA/600/D-90/172 | |||||||||||
Stock Number | PB91-131698 | |||||||||||
Additional Subjects | Furans ; Chlorine aromatic compounds ; Gas chromatography ; Mass spectroscopy ; Dioxins ; Air pollution monitoring ; Green Bay(Wisconsin) ; Air samplers | |||||||||||
Holdings |
|
|||||||||||
Collation | 7 p. : ill., tables ; 28 cm. | |||||||||||
Abstract | A short-term study for determination of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in ambient air in Green Bay, Wisconsin, has been completed. General Metals Works PS-1 air samplers equipped with particle filters and polyurethane foam (PUF) sorbent were used to sample ambient air for 24-hour periods. Analytical procedures based on high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) were used for the analysis. Total concentrations detected in ambient air for PCDDs ranged from 0.78 to 1.7 pg/cu m and those for PCDFs ranged from 0.67 to 2.6 pg/cu m. Minimum limits of detection were in the range of 0.01 to 0.08 pg/cu m. |
|||||||||||
Notes | "June 1990." |