RECORD NUMBER: 4600 OF 5789Main Title | Remote Measurement of Gaseous Pollutant Concentrations Using a Mobile Fourier Transform Interferometer System. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Herget, William F. ; Brasher, James D. ; | |||||||||||
CORP Author | Environmental Sciences Research Lab., Research Triangle Park, NC. | |||||||||||
Year Published | 1978 | |||||||||||
Report Number | EPA-600/J-79-065; | |||||||||||
Stock Number | PB80-177058 | |||||||||||
Additional Subjects | Gas analysis ; Remote sensing ; Chemical analysis ; Optical interferometers ; Industrial wastes ; Combustion products ; Mobile equipment ; Concentration(Composition) ; Exhaust emissions ; Reprints ; Air pollution detection ; Fourier transform spectroscopy ; Long path optical measurements | |||||||||||
Holdings |
|
|||||||||||
Collation | 20p | |||||||||||
Abstract | A commercial Fourier transform interferometer system with telescopic optics has been installed in a van and used to make long-path absorption and single-ended emission measurements of gaseous pollutant concentrations at a number of geographical locations. The system covers the infrared spectral region from 650 to 6000/cm at a maximum resolution of 0.06/cm. For many pollutants, concentrations in the 1-10 parts per billion range can be detected over a 1 kilometer path length. To date, measurements have been made in the absorption mode across fertilizer plant gypsum ponds, an oil refinery, and jet engine plumes; industrial stacks, waste gas flares, and jet engine plumes have been studied in the emission mode. |