Main Title |
Asbestos-containing materials in school buildings : bulk sample analysis quality assurance program : bulk sample rounds 12, 13, and blind round III / |
Author |
Pasquini, D. A. ;
Parris, M. L. ;
Starner, K.
|
Other Authors |
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC.;Environmental Monitoring Systems Lab., Research Triangle Park, NC. Quality Assurance Div. |
Publisher |
Quality Assurance Division, Environmental Monitoring System Laboratory, U.S. Environmental Protection Agency, |
Year Published |
1986 |
Report Number |
EPA/600/4-86/028; EPA-68-02-3767; EPA-68-02-4125 |
Stock Number |
PB86-222353 |
Subjects |
School buildings--United States--Safety measures ;
Asbestos in building--United States ;
Building materials--United States--Safety measures ;
Building materials--Safety measures ;
School buildings--Safety measures
|
Additional Subjects |
School buildings ;
Asbestos ;
Bulk sampling ;
Insulation ;
Quality assurance ;
Identifying ;
Air pollution ;
Indoor air pollution
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB86-222353 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
92 pages : illustrations, forms, 1 map ; 28 cm |
Abstract |
The report presents the results of laboratories participating in the twelveth, thirteenth and third (III) blind round of the bulk sample analysis quality assurance program sponsored by the U.S. Environmental Protection Agency. Three hundred twenty-three, 386 and 51 laboratories which analyze bulk samples (by polarized light microscopy) to determine asbestos content participated in these rounds, respectively. Laboratories received bulk samples of asbestos, asbestos substitutes or other bulk insulation materials. Three aspects of analytical results were considered: classification of a sample as either asbestos (positive) or nonasbestos (negative); identification of the specific type of asbestos present; and quantitation of the relative amount of major constituents present. A performance rating was assessed for each laboratory, based only on the ability to correctly classify samples. Reductions of a possible 4/4 correct score was made only for the reporting of false positives and false negatives. Samples were correctly classified as asbestos or non-asbestos containing materials (as described in Federal Register, Vol. 47, No. 103, Thursday, May 27, 1982) by 98.5%, 98.6% and 96.7% of the laboratories participating in rounds twelve, thirteen and third blind round, respectively. |
Notes |
"July 1985." "EPA/600/4-85/047." "Contract no. 68-02-3767." Microfiche. |