Main Title |
Comparisons between MM5 (Modified Method 5), OM7 (Oregon Method 7), and Draft ASTM Measurements of Wood Stove Emissions. |
Author |
McCrillis, R. C. ;
Merrill, R. G. ;
Westlin, P. R. ;
Weant, G. E. ;
Wagoner, D. E. ;
|
CORP Author |
Engineering-Science, Inc., Cary, NC. ;Radian Corp., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Year Published |
1986 |
Report Number |
EPA-68-02-3996; EPA/600/D-86/150; |
Stock Number |
PB86-223096 |
Additional Subjects |
Air pollution ;
Stoves ;
Combustion products ;
Performance ;
Wood burning appliances ;
Stationary sources ;
Air sampling
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB86-223096 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
20p |
Abstract |
The paper compares three candidate sampling methods--the EPA Modified Method 5 (MM5), the Oregon Method 7 (OM7), and the ASTM proposed Method P180--preparatory to selecting a wood stove operating procedure and related emission sampling method. (NOTE: The EPA is developing a New Source Performance Standard for wood burning stoves. This is one of several issues to be resolved during the development process). Five wood stoves (two catalytic, one noncatalytic generic, one noncatalytic high efficiency, and one catalytic fireplace insert) were tested. Results showed good correlations between the emission measurements obtained with each method. |