Main Title |
Portable Sampler for Pesticides and Semivolatile Industrial Organic Chemicals in Air. |
Author |
Lewis, Robert G. ;
MacLeod, Kathryn E. ;
|
CORP Author |
Health Effects Research Lab., Research Triangle Park, NC. |
Year Published |
1981 |
Report Number |
EPA-600/J-81-354; |
Stock Number |
PB82-246810 |
Additional Subjects |
Pesticides ;
Organic compounds ;
Samplers ;
Portable equipment ;
Design criteria ;
Performance evaluation ;
Reprints ;
Air pollution detection
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB82-246810 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
8p |
Abstract |
A battery powered, low volume air sampling system utilizing polyurethane form (PUF) as a trapping medium has been developed and evaluated. The sampler provides air flows of up to 4 L/min affording theoretical detection limits of less than 0.1 microgram/cu m for most chemicals tested. It is lightweight and portable and operates very quietly which makes it ideally suited for domicillary air sampling or as a personal air monitor. |