Main Title Environmental technology verification report : photoacoustic infrared monitor : Innova AirTech Instruments type 1312 multi-gas monitor /
Author Einfeld, Wayne.
Other Authors
Author Title of a Work
Billets, Stephen.
Koglin, Eric, N.
CORP Author Sandia National Labs., Albuquerque, NM. Environmental Characterization and Monitoring Dept.;Environmental Protection Agency, Las Vegas, NV. National Exposure Research Lab.
Publisher National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency,
Year Published 1998
Report Number EPA/600/R-98/143; NERL-LV-98-101
Stock Number PB2001-101552
Subjects Infrared detectors--Evaluation. ; Volatile organic compounds--Analysis--Technological innovations--United States--Evaluation. ; Water--Pollution--Measurement--Technological innovations--United States--Evaluation.
Additional Subjects Photoacoustic infrared monitors ; Water pollution monitoring ; Ground water ; Detectors ; Monitors ; Volatile organic compounds ; Chlorine ; Performance evaluation ; Analytical data ; Operational data ; Sampling ; Multi-gas monitors
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30003P2S.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2001-101552 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation 80 pages : illustrations, maps ; 28 cm.
Abstract
The U.S. Environmental Protection Agency. Through the Environmental Technology Verification Program, is working to accelerate the acceptance and use of innovative technologies that improve the way the United States manages its environmental problems. This report documents demonstration activities, presents demonstration data, and verifies the performance of the Innova Type 1312 Multi-gas Monitor. Reports documenting the performance of the other technologies have been published separately. The demonstration was conducted at two geologically and climatologically different sites: the U.S. Department of Energy's Savannah River Site, near Aiken, South Carolina and McClellan Air Force Base, near Sacramento California. The demonstration provided adequate analytical and operational data with which to evaluate the performance of the 1312 Multi-gas Monitor. A correlation analysis of 1312 and laboratory TCE and PCE groundwater results revealed a relatively high degree of linear correlation for Savannah River data (r > 0.98) and McClellan data (r>0.89). The type 1312 costs between $28,000 and $35,000, depending on options, and can be operated by a field technician with minimal training. Method development and analysis of multi-component samples may require a higher level of operator training and knowledge in use of the instrument. The throughput rate was in the range of one or two samples per hour. Analytical results are available at the conclusion of a sample run. The results of the demonstration show that the 1312 can provide useful, cost-effective data for routine groundwater monitoring in circumstances where the sample composition in known. As with any technology selection, the user must determine what is appropriate for the application by taking into account instrument performance and the project's data quality objectives.
Notes
"November 1998." Includes bibliographical references (page 57). "EPA/600/R-98/143." "The U.S. Environmental Protection Agency ... funded and managed, under interagency agreement no. DW89936700-01-0 with the U.S. Department of Energy's Sandia National Laboratory, the verification effort described in this document"--Page ii. "Stephen Billets and Eric Koglin, project officers." Microfiche.