Main Title Residual oxidants removal from coastal power plant cooling system discharges : field evaluation of SO2 addition system /
Author Scheyer, K. ; Houser, G.
Other Authors
Author Title of a Work
Jones, Julian W.
Houser, G.
CORP Author TRW, Inc., Redondo Beach, CA.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Office of Research and Development,
Year Published 1980
Report Number EPA 600-7-80-049; EPA-68-02-2613
Stock Number PB80-170764
OCLC Number 54101449
Subjects Cooling water. ; Dechlorination.
Additional Subjects Water pollution control ; Industrial waste treatment ; Dechlorination ; Electric power plants ; Sea water ; Sulfur dioxide ; Oxidizers ; Performance evaluation ; Sampling ; Field tests ; Laboratory equipment
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100BRBO.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EIAD  EPA-600/7-80-049 Region 2 Library/New York,NY 08/01/2003
EJBD ARCHIVE EPA 600-7-80-049 Headquarters Library/Washington,DC 10/02/2018
EJBD  EPA 600-7-80-049 Headquarters Library/Washington,DC 03/15/2019
EKAM  EPA 600/7-80-049 Region 4 Library/Atlanta,GA 07/21/1995
EKBD  EPA-600/7-80-049 Research Triangle Park Library/RTP, NC 01/30/2004
ERAD  EPA 600/7-80-049 Region 9 Library/San Francisco,CA 02/19/2013
NTIS  PB80-170764 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. 01/01/1988
Collation v, 33 leaves : illustrations, charts, photograph ; 28 cm.
Abstract
The report gives results of an evaluation of the performance of a dechlorination system that uses SO2 to remove residual oxidants from chlorinated sea water in a power plant cooling system. Samples of unchlorinated, chlorinated, and dechlorinated cooling water were obtained at Pacific Gas and Electric's Potrero power plant in San Francisco. The samples were collected during 28 sampling periods--14 at flood tide and 14 at ebb tide--and analyzed for several chemical and physical constituents. An amperometric titrator was used for field analysis of total oxidant residual (TOR) and free oxidant residual (FOR). Analytical results, plant operating data, and laboratory experiments were used to evaluate the dechlorination system. Major conclusions include: (1) the dechlorination system studied showed effective removal of residual oxidants from chlorinated sea water used in the power plant cooling system; (2) the dechlorination system proved reliable (no measurable oxidant residual was found at the effluent outfall); and (3) due to the effectiveness of the dechlorination system in removing all measurable oxidant residual, average and maximum levels of dechlorination cannot be determined.
Notes
Project Officer: Julian W. Jones. TRW, Inc. Contract Number: 68-02-2613 "EPA 600-7-80-049." "March 1980." Cover title. Includes bibliographical references.