Record Display for the EPA National Library Catalog

RECORD NUMBER: 6 OF 6

OLS Field Name OLS Field Data
Main Title Voltammetric determination of acrolein /
Author Howe, Lyman H.
CORP Author Tennessee Valley Authority, Chattanooga. Div. of Environmental Planning.;Environmental Protection Agency, Washington, D.C. Office of Energy, Minerals and Industry.
Publisher U.S. Environmental Protection Agency ; available through the National Technical Information Service,
Year Published 1976
Report Number E-EP-76-01; EPA-600/7-76.005; TVA-E-EP-76-1
Stock Number PB-260 376
OCLC Number 17575447
Subjects Acroleins.
Additional Subjects Acroleins ; Polarographic analysis ; Electrochemistry ; Chemical analysis ; Procedures ; Voltammetry
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=930004IN.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJAD  EPA 600/7-76-005 Region 3 Library/Philadelphia, PA 03/15/1996
EJBD ARCHIVE EPA 600-7-76-005 Headquarters Library/Washington,DC 03/10/2010
EJBD  EPA 600-7-76-005 c.1 Headquarters Library/Washington,DC 04/15/2014
EKAM  EPA-600/7-76.005 Region 4 Library/Atlanta,GA 07/08/1994
ELBD  EPA 600-7-76-005 AWBERC Library/Cincinnati,OH 06/25/2012
EOBD  EPA 600/7-76.005 NEIC Library/Denver,CO 05/23/2011
ESAD  EPA 600-7-76-005 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-260 376 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation vi, 42 p. : ill. ; 28 cm.
Abstract
A differential pulse polarographic method was developed for acrolein. It is based on electrochemical reduction of acrolein at the dropping mercury electrode. With this method, acrolein can be quantitated in natural and condenser cooling waters at concentrations of 0.05 to 0.5 mg/l. The sample for acrolein analysis is buffered at pH 7.2 with 0.09 M phosphate to resist changes in pH, and ethylenediaminetetraacetic acid is added in a concentration of 0.09% to prevent interference from zinc. The recovery of acrolein was unaffected by pH in the 6.8-7.6 range and by zinc at 2.0 mg/l. Replicate analyses at concentrations of 0.1 and 0.3 mg/l acrolein in reagent water gave respective standard deviations of 7.2 and 4.1% and relative errors of 2.8 and 3.3%. The recommended method is given in the appendix. Employing differential pulse voltammetry at the glassy carbon electrode, acrolein was determined with a sensitivity of 10 mg/l. The acrolein was indirectly measured by forming the sulfite complex and oxidately measuring unreacted sulfite in 0.09 M phosphate buffer at pH 7.2. The effectiveness of sulfite in preserving acrolein could not be evaluated as all attempts failed in quantitatively recovering acrolein at 0.5 mg/l in the presence of excess sulfite.
Notes
"E-EP-76-01." "EPA-600/7-76.005." "This study was conducted as part of the Federal Interagency Energy/Environment Research and Development Program."