Record Display for the EPA National Library Catalog

RECORD NUMBER: 3 OF 6

Main Title Innovative technology verification report : Niton XLi 700 Series XRF Analyzer /
CORP Author Tetra Tech EM Inc.; Tetra Tech Environmental Management, Inc., Cincinnati, OH.; Environmental Protection Agency, Las Vegas, NV. National Exposure Research Lab.
Publisher U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, Environmental Sciences Division, Characterization and Monitoring Branch,
Year Published 2006
Report Number EPA 540-R-06-003
Stock Number PB2006-109035
OCLC Number 181590622
Additional Subjects X-ray fluorescense analyser ; Performance ; Cost data ; Niton XLi 700 ; Demonstration ; Tables (data) ; Soils ; Sediment ; Trace elements ; Measurement ; Evaluation ; Innovative technology ; XRF instruments ; Superfund Innovative Technology Evaluation (SITE) ; X-ray fluorescence (XRF)
Internet Access
Description Access URL
http://www.epa.gov/nrmrl/pubs0705.html
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P1005HNK.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA 540-R-06-003 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
NTIS  PB2006-109035 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation xiv, 75, [108] pages : color illustrations, charts (some color) ; 28 cm
Abstract
The Niton XLi 700 Series (XLi) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLi analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLi analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration.
Notes
"EPA 540-R-06-003." "April 2006." Cover title. "Contract no. 68-C-00-181, task order no. 42." Includes bibliographical references (page 75).