Main Title |
Demonstration of Wellman-Lord/Allied Chemical EGD technology : boiler operating characteristics / |
Author |
Adams, R. C. ;
Eggleston, T. E. ;
Haslbeck, J. L. ;
Jordan, R. C. ;
Pulaski., Ellen
|
Other Authors |
|
CORP Author |
TRW Environmental Engineering Div., Vienna, Va.;Industrial Environmental Research Lab., Research Triangle Park, N.C. |
Publisher |
Environmental Protection Agency, Office of Energy, Minerals, and Industry, Industrial Environmental Research Laboratory ; For sale by the National Technical Information Service, |
Year Published |
1977 |
Report Number |
EPA-600-7-77-014; EPA-68-02-0235; EPA-68-02-1877 |
Stock Number |
PB-269 885 |
OCLC Number |
03825925 |
ISBN |
pbk. |
Subjects |
Boilers--Valuation ;
Flue gases--Desulfurization
|
Additional Subjects |
Boilers ;
Air pollution control ;
Sulfur dioxide ;
Coal ;
Sulfur ;
Flue gases ;
Combustion products ;
Industrial wastes ;
Performance evaluation ;
Energy consumption ;
Particles ;
Design criteria ;
Tables(Data) ;
Electrostatic precipitators ;
Wellman process ;
Retrofitting
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-7-77-014 |
c.1 |
Headquarters Library/Washington,DC |
02/19/2014 |
ELBD ARCHIVE |
EPA 600-7-77-014 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-77-014 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-269 885 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
184 pages in various pagings : illustrations ; 28 cm. |
Abstract |
The report gives results of an intensive examination and characterization of a coal-fired boiler prior to retrofit of a full scale flue gas desulfurization (FGD) unit employing the Wellman-Lord/Allied process. The test established a baseline profile of the boiler for later comparison both with design and operating conditions of other boilers for which the Wellman-Lord/Allied process is potentially applicable, and with operating performance after retrofit of the FGD unit. It also established a baseline profile during operation of the boiler at conditions other than normal which have the potential for affecting the performance of the Wellman-Lord/Allied FGD unit. Boiler operating performance was examined for its economic performance, overall energy balance, and the performance of auxiliaries. Detailed profiles of the flue gas at the proposed boiler/FGD unit interface were determined at varying boiler control settings including operation at below normal sulfur, higher than normal flue gas volumes, and higher than normal grain loadings. The tests were performed on Boiler No. 11 of Northern Indiana Public Service Company's Mitchell Power Station. |
Notes |
Prepared under contracts no. 68-02-0235 and -1877, program element no. EHE624A. Issued Feb. 1977. Includes bibliographical references. |