Main Title |
Method 1638 : determination of trace elements in ambient waters by inductively coupled plasma-mass spectrometry. |
CORP Author |
DynCorp - EENSP, Alexandria, VA. Environmental Programs Div.;Environmental Protection Agency, Washington, DC. Office of Water. |
Publisher |
U.S. Environmental Protection Agency, |
Year Published |
1995 |
Report Number |
EPA 821-R-95-031; EPA-68-C3-0337 |
Stock Number |
PB95-219937 |
OCLC Number |
32499069 |
Subjects |
Trace elements in water ;
Mass spectrometry ;
Chemistry, analytical
|
Additional Subjects |
Water pollution detection ;
Solid wastes ;
Trace amounts ;
Chemical elements ;
Test methods ;
Mass spectroscopy ;
Water analysis ;
Chemical analysis ;
Water pollution sampling ;
Ground water ;
Surface waters ;
Potable water ;
Waste water ;
Concentration(Composition) ;
Procedures ;
EPA Method 200
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EIAD |
EPA 821-R-95-031 |
|
Region 2 Library/New York,NY |
03/15/1996 |
EJAD |
EPA 821/R-95-031 |
|
Region 3 Library/Philadelphia, PA |
06/09/1995 |
EJBD |
EPA/821-R-95-031 |
|
Headquarters Library/Washington,DC |
07/21/1995 |
EJDD |
METHOD 00007 |
|
Env Science Center Library/Ft Meade,MD |
05/26/1995 |
ELBD ARCHIVE |
EPA/821-R-95-031 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 821-R-95-031 |
|
AWBERC Library/Cincinnati,OH |
10/12/2010 |
EMBR METH |
EPA/821/R-95/031 |
|
NRMRL/GWERD Library/Ada,OK |
05/26/1995 |
ERAD |
EPA 821/R-95-031 |
|
Region 9 Library/San Francisco,CA |
09/29/1995 |
ESAD |
EPA 821-R-95-031 |
|
Region 10 Library/Seattle,WA |
08/18/1995 |
NTIS |
PB95-219937 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
iv, 47 p. : 29 cm. |
Abstract |
The method is for the determination of dissolved elements in ambient waters at U.S. Environmental Protection Agency (EPA) water quality criteria (WQC) levels using inductively coupled plasma-mass spectrometry (IPC-MS). It may also be used for determination of total recoverable element concentrations in these waters. This method was developed by integrating the analytical procedures in EPA Method 200.8 with the quality control (QC) and sample handling procedures necessary to avoid contamination and ensure the validity of analytical results during sampling and analysis for metals at EPA WQC levels. This method contains QC procedures that will assure that contamination will be detected when blanks accompanying samples are analyzed. |
Notes |
"April 1995." |