Record Display for the EPA National Library Catalog

RECORD NUMBER: 33 OF 52

Main Title Field tests of industrial stoker coal-fired boilers for emissions control and efficiency improvement, site I /
Author Langsjoen, Peter L. ; Langsjoen, P. L. ; Burlingame, J. O. ; Gabrielson, J. E.
Other Authors
Author Title of a Work
Burlingame, J. O.
Gabrielson, J. E.
CORP Author KVB, Inc., Minneapolis, MN.;Industrial Environmental Research Lab., Research Triangle Park, NC.;Department of Energy, Washington, DC. Div. of Power Systems.;American Boiler Manufacturers Association, Arlington, VA.
Publisher The Branch ; U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor],
Year Published 1980
Report Number EPA-600/7-80-136a; DOE-EF-77-C-01-2609
Stock Number PB80-212822
OCLC Number 08549085
Subjects Coal-fired furnaces ; Air--Pollution--United States--Measurement ; Air--Pollution--Measurement
Additional Subjects Air pollution ; Boilers ; Stokers ; Industrial heating ; Field tests ; Data ; Flue gases ; Combustion products ; Oxygen ; Carbon dioxide ; Nitrogen oxides ; Sulfur trioxide ; Particle size distribution ; Coal ; Combustion ; Efficiency ;
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101HCJC.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA-600/7-80-136a Research Triangle Park Library/RTP, NC 02/06/2004
ELBD ARCHIVE EPA 600-7-80-136a Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD ARCHIVE EPA 600-7-80-136a AWBERC Library/Cincinnati,OH 12/15/2022
ESAD  EPA 600-7-80-136a 2 copies Region 10 Library/Seattle,WA 06/01/2016
NTIS  PB80-212822 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation v, 72 pages : illustrations ; 28 cm.
Abstract
The report gives results of field measurements made on a 70,000 lb steam/hr coal-fired overfeed stoker with traveling grate. The effects of various parameters on boiler emissions and efficiency were studied. Parameters include overfire air, excess oxygen, grate heat release, and coal properties. Measurements include O2, CO2, NO, SO2, SO3, uncontrolled particulate loading, particle size distribution of the uncontrolled flyash, and combustible content of the ash. In addition to test results and observations, the report describes the facility tested, coals fired, test equipment, and procedures. Uncontrolled particulate loading on this unit averaged 1.2 lb/million Btu at full load. Full-load NO emissions ranged from 0.2 to 0.4 lb/million Btu.
Notes
"KVB, Inc." "May 1980." "IAG/contract nos. IAG-D7-E681 (EPA), EF-77-C-01-2609 (DoE), program element no. EHE624."