Main Title |
Collaborative study of method for the determination of sulfur dioxide emissions from stationary sources (fossil fuel-fired steam generators) / |
Author |
Hamil, Henry F.
|
Other Authors |
|
CORP Author |
Southwest Research Inst., San Antonio, Tex.;National Environmental Research Center, Research Triangle Park, N.C. Quality Assurance and Environmental Monitoring Lab. |
Publisher |
Quality Assurance and Environmental Monitoring Laboratory, National Environmental Research Center, |
Year Published |
1973 |
Report Number |
PB238293; EPA-650/4-74-024; SwRI-01-3487-001 |
Stock Number |
PB238293 |
OCLC Number |
55691812 |
Subjects |
Air--Pollution--Measurement ;
Sulfur dioxide ;
Environmental monitoring ;
Steam-boilers--Environmental aspects ;
Sulphur dioxide
|
Additional Subjects |
Sulfur dioxide ;
Flue gases ;
Gas analysis ;
Electric power plants ;
Steam electric power generation ;
Air pollution ;
Sampling ;
Calibrating ;
Volumetric analysis ;
Quantitative analysis ;
Accuracy ;
Air pollution detection
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 650-4-74-024 |
|
Headquarters Library/Washington,DC |
06/09/2015 |
EKBD |
EPA-650/4-74-024 |
|
Research Triangle Park Library/RTP, NC |
08/29/2017 |
ELBD ARCHIVE |
EPA 650-4-74-024 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
NTIS |
PB-238 293 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
58 pages in various pagings : illustrations, tables ; 28 cm. |
Abstract |
A collaborative study has been performed on Method 6 promulgated by EPA for determining the concentration of sulfur dioxide emissions from stationary sources. Method 6 specified the extraction of a gas sample from the stack, the separation of the sulfur dioxide from the acid mist including sulfurtrioxide, and the measurement of the sulfur dioxide fraction as sulfate by the barium-thorin titration method. Collaborative tests were conducted at both a coal-fired steam generating power plant and an oil-fired pilot plant by the same four collaborative teams. Most (75%) of the reproducibility variation in a test result resides in the field sampling phase of Method 6, with 25% occurring in the analytical phase. Only 13% reproducibility variance is caused by repeatability sources, while 87% results from lab bias sources. |
Notes |
EPA 650/4-74-024. December 1973. Prepared for the U.S. Environmental Protection Agency. Contract Number: 68-02-0623 EPA project officer: M. Rodney Midgett. Also distributed by National Technical Information Service (NTIS) as PB238293. |