Record Display for the EPA National Library Catalog

RECORD NUMBER: 29 OF 78

Main Title Evaluation of a Sampling Method for Acetonitrile Emissions from Stationary Sources.
Author Johnson, L. D. ; Fuerst, R. G. ; Steger, J. L. ; Bursey, J. T. ;
CORP Author Eastern Research Group, Morrisville, NC.;Environmental Protection Agency, Research Triangle Park, NC. National Exposure Research Lab.
Publisher 1997
Year Published 1997
Report Number EPA-68-D4-0022; EPA/600/A-97/055;
Stock Number PB97-195465
Additional Subjects Acetonitrile ; Air pollution sampling ; Test methods ; Performance evaluation ; Air pollution detection ; Combustors ; Incinerators ; Combustion products ; Emissions ; Stationary pollutant sources ; Air pollution sources ; Chemical analysis ; Flame ionization ; Analytical methods ; Statistical analysis ; Sampling trains
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100P6SN.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB97-195465 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 12p
Abstract
This paper describes successful laboratory development and field evaluation of an effective method for sampling acetronitrile from stationary sources. The acetronitrile sampling train uses Modified Method 5 sampling procedures and hardware nearly identical to those described in US EPA Method 0010, but employs Carboxen-1000 sorbent rather than Amberlite XAD-2. A field evaluation conducted according to US EPA Method 301 demonstrated RSDs of 17% and 13% for the 20 unspiked and dynamically spiked samples, respectively. The bias was statistically insignificant, so no bias correction factor was required. The estimated detection limit for the method is 60 ppbv, using quantitation by flame ionization detector.