Record Display for the EPA National Library Catalog

RECORD NUMBER: 22 OF 59

Main Title Sandia National Laboratories In situ Electrokinetic Extraction Technology. Innovative Technology Evaluation Report.
CORP Author Tetra Tech EM, Inc., Cincinnati, OH.;National Risk Management Research Lab., Cincinnati, OH. Office of Research and Development.
Publisher May 1999
Year Published 1999
Report Number EPA-68-C5-0037; EPA/540/R-97/509;
Stock Number PB2000-101618
Additional Subjects Soil treatment ; Performance evaluation ; Land pollution control ; Soil contamination ; Chromates ; Electrokinetics ; Electrodes ; Lysimeters ; Electroosmosis ; Electromigration ; Removal ; In-situ processing ; Remediation ; Demonstration programs ; In-situ electrokinetic extracton ; Hexavalent chromium ; SITE(Superfund Innovative Technology Evaluation)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=10002AIC.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2000-101618 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 72p
Abstract
As a part of the Superfund Innovative Technology Evaluation (SITE) Program, the U.S. Environmental Protection Agency evaluated the in-Situ Electrokinetic (ISEE) system at Sandia National Laboratories, Albuquerque, New Mexico. The SITE demonstration results show that the ISEE System removed hexavalent chromium in the form of chromate from soil under unsaturated conditions. At SNLs preferred operating conditions, (1) approximately 200 grams (g) of hexavalent chromium were removed during the 700 hours of system operation, (2) the overall removal efficiency for the system was approximately 0.14 g of hexavalent chromium per kilowatt-hour (kWh), and (3) the average removal rate for the entire system was approximately 0.29 g/hour.