Main Title Process Cost Estimate for Limestone Slurry Scrubbing of Flue Gas. Part II - Detailed Estimate Sheets.
Author Calvi, E. L. ;
CORP Author Catalytic, Inc., Charlotte, N.C.
Year Published 1973
Report Number EPA-68-02-0241; R2-73-148b;
Stock Number PB-219 017
Additional Subjects ( Air pollution control equipment ; Scrubbers) ; ( Air pollution ; Sulfur dioxide) ; ( Electric power plants ; Air pollution control equipment) ; Combustion products ; Flue gases ; Cost estimates ; Capitalized costs ; Operating costs ; Labor estimates ; Limestone scrubbing ; Alkaline scrubbing ; Air pollution control
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-219 017 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 95p
Abstract
The report contains detailed estimate sheets resulting from a conceptual design and cost estimate for a wet limestone scrubbing system for removal of sulfur dioxide from the flue gas of a new 500-megawatt steam boiler plant, fired with coal containing a 3.5 percent sulfur. The estimate covers all equipment from the boiler breeching to the stack, and includes: limestone storage and processing, slurry scrubbing with stack gas reheater and accessories, and spent limestone slurry pond disposal and water recovery. The capital cost for the scrubbing system installed with a new boiler plant was estimated to be $20.15 million, or an incremental cost of $40.30 per kilowatt of installed power. The operating cost was estimated to be $7.20 million per year, or 2.06 mills per kilowatt hour of electricity generated.