Record Display for the EPA National Library Catalog

RECORD NUMBER: 23 OF 38

Main Title Low Emission Combustor/Vapor Generator for Automobile Rankine Cycle Engines.
Author Duff, T. E. ; Shekelto, J. R. ; Addom, R. B. ; Compto, W. A. ;
CORP Author Solar, San Diego, Calif.
Year Published 1973
Report Number EPA-68-04-0036; 460/3-73-004;
Stock Number PB-230 896
Additional Subjects External combustion engines ; Boilers ; Rankine cycle ; Air pollution ; Exhaust gases ; Combustion chambers ; Tests ; Automobile engines ; Working fluids
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-230 896 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 330p
Abstract
This is the final report on a program to demonstrate a low emission vapor generator for automotive Rankine cycle power plants. Program goals were to design and test a low emission system that required low parasitic power, had compact packaging, high steam generator efficiency and suitable controls for fuel, air and water for the regulation of steam pressure and temperature. A steam generator with an output of 1200 pounds per hour at 1000F and 1000 psia was demonstrated by tests to have weighed emissions below the 1976 emission standards over a simulated driving cycle.