Record Display for the EPA National Library Catalog

RECORD NUMBER: 4602 OF 4742

Main Title Use of the flame photometric detector method for measurement of sulfur dioxide in ambient air : a technical assistance document /
Author Eaton, W. C.
CORP Author Research Triangle Inst., Research Triangle Park, N.C.;Environmental Monitoring and Support Lab., Research Triangle Park, N.C.
Publisher Environmental Monitoring and Support Laboratory, U.S. Environmental Protection Agency,
Year Published 1978
Report Number EPA-600/4-78-024; EPA-68-02-2433
Stock Number PB-285 171
OCLC Number 15113691
Subjects Environmental monitoring ; Air--Pollution--Measurement ; Sulfur dioxide ; Flame photometry ; Sulphur dioxide
Additional Subjects Gas detectors ; Sulfur dioxide ; Gas analysis ; Chemical analysis ; Flame photometry ; Calibrating ; Air pollution ; Monitoring ; Sulfur ; Concentration(Composition) ; Design criteria ; Performance evaluation ; Laboratory equipment ; Air pollution detection ; Flame photometric detectors
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101A5EI.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJED  EPA 600/4-78/024 OCSPP Chemical Library/Washington,DC 03/25/2005
EKBD  EPA-600/4-78-024 Research Triangle Park Library/RTP, NC 08/01/2003
ELBD ARCHIVE EPA 600-4-78-024 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-4-78-024 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-285 171 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation xvi, 147 p. : ill., tables ; 28 cm.
Abstract
This technical assistance document is intended to serve as a source-book of information and outlines of good practice for operation and calibration of ambient air SO2 detection analyzers based on the measurement principle of Flame Photometric Detection (FPD). This is accomplished through the identification and control of critical parameters affecting the operation and calibration of FPD analyzers. The document may be used with analyzers which measure total sulfur, as well as with new SO2 specific models which have been designated as equivalent methods by EPA. This document is to be used in conjunction with the instrument manufacturer's instruction manual. The document consists of six sections: (1) Introduction to FPD principle, (2) Installation and startup of the analyzer, (3) Calibration sources and their air supplies, (4) Procedures for multipoint dynamic calibration, (5) Procedural aids, and (6) References and Index.
Notes
"May 1978." Includes bibliographical references (p. 145-146) and index. Prepared for Environmental Monitoring and Support Laboratory, U.S. Environmental Protection Agency.
Contents Notes
This Technical Assistance Document is intended to serve as a source-book of information and outlines of good practice for operation and calibration of ambient air SOb2s detection analyzers based on the measurement principle of Flame Photometric Detection (FPD). This is accomplished through the identification and control of critical parameters affecting the operation and calibration of FPD analyzers. The document may be used with analyzers which measure total sulfur, as well as with new SOb2s-specific models which have been designated as equivalent methods by EPA.