Record Display for the EPA National Library Catalog

RECORD NUMBER: 6 OF 7

Main Title Percutaneous Absorption of D4 (Octamethylcyclotetrasiloxane).
CORP Author Dow Corning Corp., Midland, MI.; Environmental Protection Agency, Washington, DC. Office of Toxic Substances.
Year Published 1994
Report Number 86940001691
Stock Number OTS0557972
Additional Subjects Toxicology ; Health effects ; Octamethylcyclotetrasiloxane (556-67-2) ; Pharmaco Kinetics ; Mammals ; Humans ; In Vitro ; Toxic substances ; Laboratory animals ; CAS No 556-67-2
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  OTS0557972 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 104p
Abstract
This study evaluated the percutaneous absorption of dimethylcyclosiloxane fluid. Four tissue samples from each of 3 human cadavers was used for these in vitro studies. Five ul doses containing 1.5 uCi radiolabelled dimethylcyclosiloxane fluid were applied to each 1 square centimeter tissue sample. Skin integrity was also evaluated by histopathological examination. Histopathological examination indicated no lesions on the tissue sections. After 24 hours, the total percutaneous absorption (skin compartment and amount absorbed through the skin) was 0.29 percent, 0.47 percent, and 4.4 percent of the applied amount. Greater than 80 percent of the total compound recovered was found in the air traps confirming the relative volatility of this compound. Under conditions of this experiment, the compound was found to volatilize prior to significant absorption.