Record Display for the EPA National Library Catalog

RECORD NUMBER: 44 OF 111

Main Title Evaluation of the advanced low-NOx burner, Exxon, and Hitachi Zosen DeNOx process /
Author Maxwell, J. D. ; Humphries, L. R.
Other Authors
Author Title of a Work
Humphries, L. R.
CORP Author Tennessee Valley Authority, Muscle Shoals, AL. Div. of Energy Demonstrations and Technology.;Industrial Environmental Research Lab., Research Triangle, Park, NC.
Publisher U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; Tennessse Valley Authority, Office Power, Energy Demonstrations and Technology ; National Technical Information Service [distributor],
Year Published 1981
Report Number TVA/OP/EDT-81-28; EPA-600/7-81-120
Stock Number PB82-192543
OCLC Number 07853298
Subjects Flue gases--Purification ; Flue gases--Purification--Economic aspects ; Nitrogen compounds ; Air--Pollution ; Air--Pollution--Economic aspects
Additional Subjects Air pollution control ; Nitrogen oxides ; Cost analysis ; Capitalized costs ; Design criteria ; Performance evaluation ; Industrial wastes ; Combustion products ; Exxon process ; Hitachi zosen process
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=20006RMI.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  EPA-600/7-81-120 Region 1 Library/Boston,MA 05/25/2016
EJBD  EPA 600-7-81-120 c.1 Headquarters Library/Washington,DC 06/04/2013
EKBD  EPA-600/7-81-120 Research Triangle Park Library/RTP, NC 12/05/2003
ELBD ARCHIVE EPA 600-7-81-120 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-7-81-120 Region 10 Library/Seattle,WA 04/12/2017
NTIS  PB82-192543 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation xxvii, 112 pages : illustrations ; 28 cm.
Abstract
The report is a technical discussion and preliminary economic evaluation of six NOx control methods: three at 50% NOx reduction, and three at 90%. The basecase power plant is a new 500-MW coal-fired unit emitting 0.6 lb NO2/million Btu in the flue gas. The three 50% NOx reduction processes are the EPA-sponsored advanced low-NOx burner (ALNB), the Exxon Thermal DeNOx process, and the Hitachi Zosen process, which have capital investments of $4.8, $19.7, and $31.4/kW, respectively, and levelized annual revenue requirements of 0.20, 1.9, and 4.7 mills/kWh, respectively. For 90% NOx reduction, the ALNB process is combined with the Hitachi Zosen process, the Exxon process is combined with the Hitachi Zosen process, and the Hitachi Zosen process is used alone. Capital investment and levelized annual revenue requirements for these three processes are $51.8/kW and 6.7 mills/kWh for the ALNB/Hitachi Zosen process, $64.2/kW and 8.2 mills/kWh for the Exxon/Hitachi Zosen process, and $50.9/kW and 7.9 mills/kWh for the Hitachi Zosen process alone. The ALNB, a combustion modification, is the least expensive NOx control method. As expected, the costs for obtaining high levels of NOx reduction (90%) are significantly greater than for more moderate levels (50%).
Notes
Prepared for U.S. Environmental Protection Agency, Office of Research and Development by the Tennessee Valley Authority, Office of Power, Division of Energy Demonstrations and Technology under EPA Interagency agreement no. Contract Number: 79-D-X0511, program element no. Final report. Bibliography: pages 88-90. July 1981.