Record Display for the EPA National Library Catalog

RECORD NUMBER: 343 OF 491

Main Title Performance of an Electrical Resistivity Technique for Detecting and Locating Geomembrane Failures.
Author Shultz, D. W. ; Duff, B. M. ; Peters, W. R. ;
CORP Author Southwest Research Inst., San Antonio, TX.;Municipal Environmental Research Lab., Cincinnati, OH.
Year Published 1984
Report Number EPA-68-03-3033; EPA-600/D-84-123;
Stock Number PB84-190594
Additional Subjects Membranes ; Failure analysis ; Leakage ; Linings ; Mathematical models ; Electrical resistivity ; Performance evaluation ; Hazardous materials ; Earth fills ; Assessments ; Plastics ; Elastomers ; Soils ; Geomembrane ; Liquid waste disposal ; Impoundments ; Computer applications
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB84-190594 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 16p
Abstract
An electrical resistivity survey technique has been developed and tested for assessing the integrity of geomembrane liner systems installed in fluid impoundments. Development of the technique has included two-dimensional computer modeling and three-dimensional physical model testing. A one-acre geomembrane lined surface impoundment was used for full-scale testing of the technique. Tests were conducted to detect and locate single and multiple leaks of different sizes. Results indicate the technique can be used to detect and locate single and multiple leaks as small as one inch in diameter with an accuracy of five feet or less.