Record Display for the EPA National Library Catalog

RECORD NUMBER: 60 OF 147

Main Title Flue gas desulfurization : the state of the art /
Author Srivastava, Ravi K. ; Brna, T. G. ; Sedman, C. B. ; Culligan, K. ; Jozewicz, W.
Other Authors
Author Title of a Work
Brna, T. G.
Sedman, Charles B.
Jozewicz, Wojciech.
Culligan, K.
CORP Author ARCADIS Geraghty and Miller, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Publisher U.S. Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Air Pollution Prevention and Control Division,
Year Published 2000
Report Number NRMRL-RTP-P-545; EPA/600/A-00/093; EPA-68-C-99-201
Stock Number PB2001-101291
Additional Subjects Scrubbers ; Flue gases ; Desulfurization ; Pollution control ; Air pollution abatement ; Sulfur dioxide ; Limestone ; Cost models ; Capital costs ; Emissions ; Requirements ; Acid rain ; Combustion ; Combustion products ; Electric power generation ; Coal ; Stationary pollutant sources ; LSD(Lime spray dryers) ; LSFO(Limestone forced oxidation)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2001-101291 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 22 pages : illustrations ; 28 cm
Abstract
The paper gives results of a review of commercially available flue gas desulfurization (FGD) technologies that have an established record of full-scale performance. Data on worldwide FGD applications reveal that wet FGD technologies have been used at most installations. Among the 668 worldwide FGD technology installations completed through 1998, 544 (or 81%) have wet FGD systems. The SO2 removal performance of scrubbers has been reviewed. Data reflect that most wet limestone and lime spray drying installations appear to be capable of about 90% SO2 removal. Advanced, state-of-the-art wet scrubbers can provide SO2 removal in excess of 95%. Costs associated with wet limestone forced oxidation (LSFO) and lime spray dryer (LSD) technologies are analyzed with state-of-the-art cost models. Analyses of LSFO and LSD capital costs indicate an economy of scale over a range of unit size considered.
Notes
"Ravi K. Srivastava, project officer." "EPA/600/A-00/093." "PB2001-101291." "Presented at the Conference on Air Quality II Mercury, Trace Elements, and Particulate Matter, McLean, VA, September 19-21, 2000." Microfiche.