Record Display for the EPA National Library Catalog

RECORD NUMBER: 180 OF 196

Main Title Techniques Affecting Precision and Accuracy in Hydrolysis Rate Constant Determinations of Volatile Organic Compounds Using Jeffers' Zero Headspace Reaction Bulbs.
Author Trusty, C. D. ; Ellington, J. J. ;
CORP Author Environmental Research Lab., Athens, GA. ;Technology Applications, Inc., Athens, GA.
Publisher c1991
Year Published 1991
Report Number EPA/600/J-91/137;
Stock Number PB91-216291
Additional Subjects Chloroethanes ; Hydrolysis ; Reaction kinetics ; Volatile organic compounds ; Gas chromatography ; Arrhenius equation ; Evaluation ; Reprints ; Zero headspace bulbs
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB91-216291 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 22p
Abstract
A recently published method for measurement of hydrolysis rate constants for volatile organic compounds in aqueous samples was adopted for use in the laboratory. In applying the method, the authors developed the capability to make the zero-headspace reaction bulbs and used them to measure the hydrolysis rate constant for 1,1,1-trichloroethane. After establishing and mastering the critical points of the technique, they were able to determine an acceptable neutral hydrolysis rate constant (kn=7.98 E-2, 115 C) that was within 17% of the value calculated using the Arrhenius parameters of Jeffers' method. A detailed description of their experiences while learning this technique and becoming proficient in its use is provided in the belief that the experience would benefit other analytical chemists. (Copyright (c) Marcel Dekker, Inc., 1991.)