Record Display for the EPA National Library Catalog
RECORD NUMBER: 24 OF 34Main Title | Sandia National Laboratories In situ Electrokinetic Extraction Technology. Innovative Technology Evaluation Report. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CORP Author | Tetra Tech EM, Inc., Cincinnati, OH.;National Risk Management Research Lab., Cincinnati, OH. Office of Research and Development. | |||||||||||
Publisher | May 1999 | |||||||||||
Year Published | 1999 | |||||||||||
Report Number | EPA-68-C5-0037; EPA/540/R-97/509; | |||||||||||
Stock Number | PB2000-101618 | |||||||||||
Additional Subjects | Soil treatment ; Performance evaluation ; Land pollution control ; Soil contamination ; Chromates ; Electrokinetics ; Electrodes ; Lysimeters ; Electroosmosis ; Electromigration ; Removal ; In-situ processing ; Remediation ; Demonstration programs ; In-situ electrokinetic extracton ; Hexavalent chromium ; SITE(Superfund Innovative Technology Evaluation) | |||||||||||
Internet Access |
|
|||||||||||
Holdings |
|
|||||||||||
Collation | 72p | |||||||||||
Abstract | As a part of the Superfund Innovative Technology Evaluation (SITE) Program, the U.S. Environmental Protection Agency evaluated the in-Situ Electrokinetic (ISEE) system at Sandia National Laboratories, Albuquerque, New Mexico. The SITE demonstration results show that the ISEE System removed hexavalent chromium in the form of chromate from soil under unsaturated conditions. At SNLs preferred operating conditions, (1) approximately 200 grams (g) of hexavalent chromium were removed during the 700 hours of system operation, (2) the overall removal efficiency for the system was approximately 0.14 g of hexavalent chromium per kilowatt-hour (kWh), and (3) the average removal rate for the entire system was approximately 0.29 g/hour. |