Record Display for the EPA National Library Catalog

RECORD NUMBER: 60 OF 65

Main Title Superfund record of decision : Velsicol Chemical Corporation, Hardeman County (O.U. 2), TN.
CORP Author Environmental Protection Agency, Washington, DC. Office of Emergency and Remedial Response.
Publisher U.S. Environmental Protection Agency, Office of Emergency and Remedial Response], Distributed by National Technical Information Service,
Year Published 1995
Report Number EPA/ROD/R04-95/256
Stock Number PB95-964039
OCLC Number 37227744
Subjects Hazardous waste sites--Tennessee
Additional Subjects Superfund ; Hazardous materials ; Waste disposal ; Land pollution control ; Pesticides ; Soil contamination ; Containment ; Capping ; Drainage systems ; Trenches ; Ground water ; Water pollution monitoring ; Water pollution abatement ; Remedial action ; Tennessee ; Record of Decision ; Toone(Tennessee) ; Hardeman County(Tennessee) ; Volatile organic compounds ; Base/neutral and acid extractable compounds
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100L85S.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA ROD-R04-95-256 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD  EPA ROD-R04-95-256 AWBERC Library/Cincinnati,OH 08/27/1999
NTIS  PB95-964039 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 v. (various pagings) : ill., maps ; 28 cm.
Abstract
This decision document presents the selected remedial action for the Velsicol Hardeman County Landfill, Operable Unit No. 2, in Toone, Hardeman County, Tennessee. The remedy includes capping the 27-acre landfill with a RCRA composite cap to reduce infiltration of surface water through the waste and contaminated soil. The RCRA composite cap consists of: scarifying existing vegetative cover and recompacting; a 40-mil high density polyethylene (HDPE) synthetic liner or equivalent, placed over the recompacted clay surface; a sand drainage blanket with a minimum hydraulic conductivity of 1 x 10-3 cm/sec placed over the liner to provide lateral drainage; the sand will be covered with a filter fabric and a layer of common fill and topsoil; a vegetative cover will be established to prevent erosion of the fill and topsoil materials; and routine monitoring of the RCRA cap in order to maintain the integrity of the cap.
Notes
Cover title. "9/26/1995." "PB95-964039." "EPA/ROD/R04-95/256." "March 1996."