Main Title Feasibility study for the development of a multifunctional emission detector for air pollutants based on homogeneous chemiluminescent gas phase reactions /
Author Fontijn, A. ; Sabadel, Alberto J. ; Ronc, Richard J.
Other Authors
Author Title of a Work
Sabadell, Alberto J.
Ronco, Richard J.
CORP Author AeroChem Research Labs., Inc., Princeton, N.J.
Publisher AeroChem Research Laboratories,
Year Published 1969
Report Number TP-217; APTD-1300; CPA-22-69-11
Stock Number PB-188 104
OCLC Number 40558562
Additional Subjects ( Air pollution ; Gas detectors) ; ( Chemiluminescence ; Gas detectors) ; ( Ozone ; Gas detectors) ; ( Carbon monoxide ; Gas detectors) ; Feasibility studies ; Monitors ; Nitrogen oxides ; Design ; Nitrogen oxide(NO)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100667B.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA/APTD-1300 Research Triangle Park Library/RTP, NC 12/31/1998
ELBD ARCHIVE EPA APTD-1300 AWBERC Library/Cincinnati,OH 01/25/2024
ESAD  APTD-1300 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-188 104 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation vi, 25 p. : ill. ; 28 cm.
Abstract
The reactions of common air pollutants, such as NO, NO2, and CO, with certain second reactants, such as ozone or O atoms, result in light emission. In a detector based on this principle, ambient air and the second reactant can be continuously flown through and mixed in a reactor under moderate vacuum. After calibration a continuous record of pollutant concentration can be obtained. Specific sensitivity to a given pollutant is obtained by a suitable choice of the second reactant and a light filter. To demonstrate the feasibility of the method, the detection of NO using O3 has been studied experimentally. A linear response from about 4 ppb NO to at least 100 ppm NO is obtained. NO2, CO2, CO, C2H4, NH3, SO2, and H2O in concentrations found in polluted air do not interfere with NO monitoring. Based on these results and data for other chemiluminescent reactions, it is shown that homogeneous chemiluminescence monitors for O3, NOx = NO + NO2 and CO can probably also be developed. A comparison of various methods of photomultiplier tube output measurement has been made. (Author)
Notes
Prepared by AeroChem Research Laboratories, a subsidiary of Sybron Corp., for the National Center for Air Pollution Control, Public Health Service. "September 1969." Includes bibliographical references (p. 17-18). Final Report. "AeroChem TP-217." PB-188 104.