Record Display for the EPA National Library Catalog

RECORD NUMBER: 2 OF 3

Main Title Restricting Dust Emission from Forced-Draft Boiler Installations, Capacity 30 Ton/Hr and Over, Hard Coal-Dust Fired with Dry Ash Removal (Staubauswurfbegrenzung Dampferzeuger ueber 10 t/h Leistung Steinkohlen-Staubfeuerungen mit trockenem Ascheabzug).
CORP Author Public Health Service, Washington, D.C.;Environmental Protection Agency, Raleigh, N.C. Air Pollution Control Office.
Year Published 1961
Report Number APTD-1586;
Stock Number PB-250 524
Additional Subjects Boilers ; Air pollution control equipment ; Standards ; Combustion products ; Flue gases ; Flue dust ; Coal ; Chimneys ; Dust collection ; Translations ; West Germany ; Forced flow boilers
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-250 524 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 30p
Abstract
The purposes of these specifications are to describe parts of the installation in which dust occurs; to characterize the influences leading to the formation of dust; to point out measures for the selection of suitable dust-removal installations and their maintenance; and, to establish guide lines for the restriction of dust emission by new installations.