Main Title |
Field tests of industrial stoker coal-fired boilers for emissions control and efficiency improvement, site J, data supplement / |
Author |
Burlingame, J. O. ;
Parker, R. A. ;
Jackson, W. M. ;
Demont, J. D.
|
Other Authors |
|
CORP Author |
KVB, Inc., Minneapolis, MN.;Industrial Environmental Research Lab., Research Triangle Park, NC.;Department of Energy, Washington, DC. Div. of Power Systems.;American Boiler Manufacturers Association, Arlington, VA. |
Publisher |
The Office ; Available to the public through the National Technical Information Service, |
Year Published |
1980 |
Report Number |
EPA-600/7-80-137b; KVB-4-15900-545; DOE-EF-77-C-01-2609 |
Stock Number |
PB80-212970 |
OCLC Number |
07793460 |
Subjects |
Coal-fired furnaces--Testing ;
Coal-fired furnaces--Environmental aspects ;
Flue gases--Measurement ;
Fly ash--Measurement
|
Additional Subjects |
Air pollution abatement ;
Boilers ;
Stokers ;
Industrial heating ;
Field tests ;
Data ;
Flue gases ;
Combustion products ;
Oxygen ;
Carbon dioxide ;
Nitrogen oxides ;
Sulfur dioxide ;
Sulfur trioxide ;
Particle size distribution ;
Coal ;
Combustion ;
Efficiency
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600/7-80-137b |
|
Headquarters Library/Washington,DC |
07/08/2005 |
EKBD |
EPA-600/7-80-137b |
|
Research Triangle Park Library/RTP, NC |
02/06/2004 |
ELBD ARCHIVE |
EPA 600/7-80-137b |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-80-137b |
2 copies |
Region 10 Library/Seattle,WA |
06/01/2016 |
NTIS |
PB80-212970 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
viii, 135 pages ; 28 cm. |
Abstract |
The Data Supplement is a compilation of test data presented in greater detail than was practical in the final technical report. It is intended to provide the necessary details to other researchers who are interested in performing their own analysis. Readers are referred to the contract final report for information as to objectives, description of facility tested and coals fired, test equipment and procedures, interpretations, and conclusions. The final technical report also contains data summaries not found in ths supplement. The Supplement contains panel board data for each test, detailed particulate, O2, CO2, NO, SO2, and SO3 data, particle size distribution data, chemical analysis of the coal, coal size consistency data, and combustible analysis and overfire traverse data. |
Notes |
Tables. "Industrial Environmental Research Laboratory, Office of Environmental Engineering and Technology, Research Triangle Park, N.C." "KVB, Inc." "May 1980." "IAG/contract nos. IAG-D7-E681 (EPA), EF-77-C-01-2609 (DoE), program element no. EHE624." |