Record Display for the EPA National Library Catalog

RECORD NUMBER: 29 OF 131

Main Title Environmental technology verification dust suppressant products : SynTech Products Corporation's TechSuppress / [electronic resource] :
CORP Author RTI International, Research Triangle Park, NC. ;Midwest Research Inst., Kansas City, MO.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Publisher U.S. Environmental Protection Agency, Office of Research and Development, Air Pollution Prevention and Control Division, National Risk Management Research Laboratory,
Year Published 2006
Report Number EPA/600/R-05/129
Stock Number PB2006-111232
Subjects Dust control ; Air quality--Equipment and supplies--Testing
Additional Subjects Air pollution control ; Dust control ; Verification ; Quality control ; Quality assurance ; Test conditions ; Traffic ; Area climate conditions ; Particulate concentration ; Environmental Technology Verification Program ; TechSuppress ; SynTech Products Corporation ; Environmental Protection Agency
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P1001GXE.PDF
http://www.epa.gov/etv/pubs/600r05129.pdf
Abstract http://www.epa.gov/nrmrl/pubs/600r05129/600r05129.htm
Verification statement http://www.epa.gov/etv/pubs/600r05129s.pdf
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2006-111232 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 online resource (x, 15 p.) : ill., charts, digital, PDF file.
Abstract
Dust suppressant products used to control particulate emissions from unpaved roads are among the technologies evaluated by the Air Pollution Control Technology (APCT) Verification Center, part of the U.S. Environmental Protection Agency's Environmental Technology Verification (ETV) Program. The critical performance factor for dust suppressant verification is the dust control efficiency (CE). CE was evaluated in terms of total particulate (TP), particulate matter less than or equal to 10 micrometers (mm) in aerodynamic diameter (PM10), and particulate matter less than or equal to 2.5 mm in aerodynamic diameter (PM2.5). SynTech Products Corporation submitted the TechSuppress dust suppressant to the APCT Center for testing. The test and quality assurance (QA) plan, prepared in accordance with the Generic Verification Protocol (GVP), addressed the site-specific issues associated with these 1-year verification tests. The 1-year testing was conducted at Fort Leonard Wood, Missouri, during October 2002, May 2003, and October 2003. This verification report summarizes the results of the 1-year test. The verified CE will be based on all tests at each site, as specified in the test/QA plan. Test conditions were measured and documented.
Notes
"January 2006". "EPA/600/R-05/129." Title from title screen (viewed on Nov. 12, 2010). Includes bibliographical references (p. 15).