Record Display for the EPA National Library Catalog

RECORD NUMBER: 651 OF 995

Main Title National dioxin study tier 4 : combustion sources : final test : site 1 : sewage sludge incinerator SSI : A /
Author Keller, Lawrence E. ; Blackley, C. R. ; Jongleux, R. F.
Other Authors
Author Title of a Work
Blackley, Candace R.
Jongleux, Robert F.
CORP Author United States. Environmental Protection Agency. Office of Air Quality Planning and Standards.; United States. Environmental Protection Agency. Office of Research and Development.; Radian Corp., Research Triangle Park, NC.; Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Publisher U.S. Environmental Protection Agency, Office of Air and Radiation, Office of Air Quality Planning and Standards ; Office of Research and Development,
Year Published 1987
Report Number EPA-450/4-84-014 j; EPA-68-03-3148; PB87233250
Stock Number PB87-233250
OCLC Number 16812601
Subjects Dioxins ; Combustion ; Sewage sludge--Environmental aspects--United States ; Tetrachlorodibenzodioxin ; Combustion ; Dioxins ; Sewage sludge--Environmental aspects ; Tetrachlorodibenzodioxin ; United States
Additional Subjects Dioxins--Environmental aspects ; Combustion ; Sewage sludge ; Air pollution ; Combustion products ; Chlorine organic compounds ; Fly ash ; Flue gases ; Reviews ; Pesticides ; Tables(Data) ; Stationary sources ; Emission factors ; Dioxins ; Dibenzodioxin/tetrachloro ; Dibenzofurans
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=00002KUM.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA-450/4-84-014j Research Triangle Park Library/RTP, NC 01/01/1988
ELBD ARCHIVE EPA 450-4-84-014j Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ERAD  EPA 450/4-84-014j Region 9 Library/San Francisco,CA 02/04/2013
ESAD  EPA 450-4-84-014J Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB87-233250 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 v. (various pagings) : ill. ; 28 cm.
Abstract
The report summarizes the results of a dioxin/furan emissions test of a multiple hearth sewage sludge incinerator equipped with a wet scrubber system for particulate emissions control. The test was the first in a series of thirteen dioxin/furan emissions tests conducted under Tier 4 of the National Dioxin Study. The primary objective of Tier 4 is to determine if various combustion sources are sources of dioxin and/or furan emissions. If any of the combustion sources are found to emit dioxin or furan, the secondary objective of Tier 4 is to quantify these emissions. Sewage sludge incinerators are one of eight combustion sources categories tested in the Tier 4 program. The tested incinerator was included in the Tier 4 study because it was considered to be fairly typical of the multiple hearth sewage sludge incineration source category. Data presented in the report include dioxin (tetra through octa homologue +2378 TCDD) and furan (tetra through octa homologue +2378 TCDD) results for both stack samples and ash samples. In addition, process data collected during sampling are also presented.
Notes
Final. "Radian Corporation." Distributed to depository libraries in microfiche. "April 1987." "EPA-450/4-84-014j."