Record Display for the EPA National Library Catalog

RECORD NUMBER: 15 OF 16

Main Title Stack tests at Kennecott Copper Corp., Hayden, Arizona Smelter /
Author Larkin, R. ; Steiner, James ; Larkin., Robert
Other Authors
Author Title of a Work
Steiner, J.
CORP Author Acurex Corp., Mountain View, Calif. Aerotherm Div.;Environmental Protection Agency, San Francisco, Calif. Region IX.
Publisher U.S. Environmental Protection Agency, Region IX, Enforcement Division,
Year Published 1977
Report Number EPA 909-9-77-002; Aerotherm-FR-77-244; EPA-68-01-3158
Stock Number PB-272 886
OCLC Number 192138508
Additional Subjects Chimneys ; Reverberatory furnaces ; Chemical industry ; Sulfuric acid ; Gas analysis ; Smelters ; Industrial wastes ; Combustion products ; Particles ; Sulfur dioxide ; Concentration(Composition) ; Sampling ; Chemical analysis ; Regulations ; Sources ; Laboratory equipment ; Design criteria ; Air pollution ; Copper smelters ; Air pollution detection ; EPA region 9 ; Hayden(Arizona) ; EPA method 5 ; EPA method 8 ; Procedures ; EPA method 3 ; Point sources
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9100A9T7.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ERAD  EPA 909/9-77-002 Region 9 Library/San Francisco,CA 06/07/2011
NTIS  PB-272 886 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 volume (various pagings) : illustrations, charts ; 28 cm
Abstract
In August and December 1976 at the request of EPA, Region IX, Enforcement Division, the Aerotherm Division of the Acurex Corporation conducted a series of air pollutant mass emissions tests at the Ray Mines Division copper smelter of the Kennecott Copper Corporation located in Hayden, Arizona. The tests were conducted at the reverberatory furnace stack in August 1976 and at the sulfuric acid plant stack in December 1976. Tests for particulate matter (Method 5), sulfur dioxide and sulfuric acid (Method 8) were conducted at each location using a combined sampling train. In addition two tests for condensable particulate matter were conducted at the reverberatory furnace stack using the combined Method 5 and 8 sampling train with an instack filter added. (Portions of this document are not fully legible)
Notes
Cover title. "EPA 909-9-77-002." "Aerotherm project 7211." "May 1977." "Aerotherm final report 77-244." "Prepared for EPA project officer - J. Busik, EPA Task Officer - L. Bowerman, Environmental Protection Agency, Enforcement Division, EPA Region IX." "Contract 68-02-3158, Task 12."