Main Title Particulate control mobile test units : first year's operation /
Author Opferkuch, Robert E.
CORP Author Monsanto Research Corp., Dayton, Ohio.;Industrial Environmental Research Lab., Research Triangle Park, N.C.
Publisher Environmental Protection Agency, Office of Research and Development ; For sale by the National Technical Information Service,
Year Published 1976
Report Number EPA-600/2-76-042; EPA-68-02-1816; EPA-ROAP-21ADM-034
Stock Number 22161
OCLC Number 02909136
ISBN pbk.
Subjects Dust--Removal ; Scrubber (Chemical technology) ; Filters and filtration
Additional Subjects Particles ; Air pollution control equipment ; Electric power plants ; Fines ; Combustion products ; Coal ; Dust collectors ; Fabric filters ; Scrubbers ; Absorbers(Materials) ; Particle size ; Performance evaluation ; Field tests ; Mobility ; Mobile equipment ; Wet methods ; Venturi separators
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=91014R0O.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EKBD  EPA-600/2-76-042 Research Triangle Park Library/RTP, NC 06/13/2003
ELBD ARCHIVE EPA 600-2-76-042 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-2-76-042 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-251 722 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation vi, 64 pages : illustrations, graphs ; 28 cm.
Abstract
The report summarizes the first year of operation of EPA-owned mobile test units that are being used in the field to study the applicability of different control methods to the control of fine particulate emitted from a wide variety of sources. Two mobile units are described: a fabric filter (baghouse) and a wet scrubber. The latter includes two types: venturi and sieve tray. Results from the baghouse tests on a coal-fired power plant indicate suitability of a baghouse, with woven glass bags, for control of dust from this type of source. Results from tests on a pulp mill lime recovery kiln show high dust removal efficiency; however, the associated high moisture content of the gases portends operating problems sufficient to indicate that a baghouse would be unsuitable for control of dust from this source. Operation of the mobile scrubber unit during the year was confined to startup testing and correction of mechanical and operating difficulties.
Notes
Prepared by Monsanto Research Corporation, Dayton, Ohio, under contract no. 68-02-1816, ROAP no. 21ADM-034, program element no. 1AB012. Includes appendices. Includes bibliographical references (page 49).