Record Display for the EPA National Library Catalog

RECORD NUMBER: 97 OF 102

Main Title Survey of laboratory studies relating to the sorption/desorption of contaminants on selected well casing materials /
Author Llopis, José L. ; Llopis, Jos e L.
CORP Author Environmental Protection Agency, Washington, DC. Office of Solid Waste and Emergency Response. ;Army Engineer Waterways Experiment Station, Vicksburg, MS. Geotechnical Lab.
Publisher U.S. Environmental Protection Agency, Office of Research and Development, Office of Solid Waste and Emergency Response,
Year Published 1992
Report Number EPA/540/4-91/005; PB92-224724
Stock Number PB92-224724
OCLC Number 27159879
Subjects Groundwater--Quality ; Pollution control equipment--Evaluation ; Water, Underground--Quality
Additional Subjects Coverings ; Water wells ; Water pollution ; Desorption ; Leaching ; Adsorption ; Monitoring ; Microorganisims control(Water) ; Concentration(Composition) ; pH ; Ionization ; Salinity ; Dissolved gases ; Oxygen ; Oxidation ; Algae ; Trace elements ; Superfund
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=600016K0.PDF
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=40001I75.PDF
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=40001I6P.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 540-4-91-005 Headquarters Library/Washington,DC 04/22/2014
ELBD ARCHIVE EPA 540-4-91-005 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD  EPA 540-4-91-005 AWBERC Library/Cincinnati,OH 03/28/1998
NTIS  PB92-224724 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Edition Rev. Aug. 1992.
Collation 15 pages ; 28 cm.
Abstract
The Regional Superfund Ground Water Forum is a group of ground-water scientists representing U.S. Environmental Protection Agency's (U.S. EPA's) Regional Offices, organized to exchange up-to-date information related to ground-water remediation at hazardous waste sites. Well casing materials used at hazardous waste sites is an issue identified by the forum as a concern of CERCLA decision makers. All aspects of a ground-water sampling program have the potential to affect the composition of a ground-water sample. The high degree of accuracy (parts per billion (ppb) range) required of some chemical analysis dictates that all potential sources of error of a ground-water sampling program be identified and sources of error in such aspects be minimized. Selection of the proper casing material for monitoring wells has been a subject of much controversy since the publication of the U.S.
Notes
Caption title. Shipping list no.: 1992-0571-P. Includes bibliographical references (pages 13-14). "EPA/540/4-91/005."