Record Display for the EPA National Library Catalog

RECORD NUMBER: 60 OF 154

Main Title Evaluation of utility boiler radiant furnace resident time/temperature characteristics : field tests and heat transfer modeling /
Other Authors
Author Title of a Work
Cetegen, B.
W. Richerter,
Reese, J. L.,
LaFond, J.,
Folsom, B. A.,
Payne, R.
Lachapelle, David G.,
Publisher U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory, Center for Environmental Information
Year Published 1987
Report Number EPA/600-S7-87-018
OCLC Number 896735180
Subjects Boilers--Environmental aspects ; Combustion gases--Environmental aspects ; Air quality management--United States
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000TJWF.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-S7-87-018 In Binder Headquarters Library/Washington,DC 10/18/2018
ELBD ARCHIVE EPA 600-S7-87-018 In Binder Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
Collation 11 pages : illustrations ; 28 cm
Notes
Caption title. At head of title: Project summary. "Sept. 1987." "EPA/600-S7-87-018."
Contents Notes
This report describes an investigation of the adequacy of a modeling approach in predicting the thermal environment and flow field of pulverized-coal-fired utility boilers. Two 420 MW[subscript 3] coal-fired boilers were evaluated: a single-wall-fired unit and a tangentially fired unit, representing the two commonest boilers in the U.S. Extensive field measurements were conducted on each unit to determine detailed temperature, heat flux, gas species composition, and flow field data for a range of operating conditions. Separate modeling approaches were used to predict boiler thermal performance and flow characteristics. A three-dimensional zone method of analysis was used to predict local and overall heat transfer, temperature profiles, and fuel burnout. Such predictive tools provide a sophisticated treatment of radiative heat transfer, but are decoupled from the furnace flow field. This input to the heat transfer code was obtained from detailed measurements in reduced scale isothermal physical flow models of the two boilers. Comparisons between model predictions and the detailed field measurement data have demonstrated the viability of this approach in predicting furnace performance, and in extrapolating limited available data to alternate operating conditions. Overall thermal performance can, in general, be accurately predicted; however, the analysis has shown that the correct quantitative prediction of local temperatures and other properties requires anaccuratee specification of inhomogeneities in boilerinputu conditions, in the boiler flow field, and in the local distribution of wall ash deposits.